Research connecting computing, power and thermal management

DAILY RESEARCH EDITIONCooling · Compute–power coordination · AI infrastructure

In focus/ Research highlights

8 papers5 research areas

Cooling & thermal management/ In focus

Maximizing Compute Capacity in AI Data Centers through Cooling, Energy Storage, and Computing Adaptation

The deployment of artificial intelligence is increasingly constrained by limited site-level power capacity, which must support both compute systems and non-compute systems (primarily cooling) at all times. Cooling power demand, especially in non-evaporative cooling systems, can increase substantially with ambient temperature in the summer, producing recurring periods of elevated cooling power that often lasts for multiple hours per day. Therefore, maximizing compute capacity under a limited site-level power budget is an important planning and operational challenge. Sizing the compute system conservatively based on peak cooling power can leave part of the site-level power capacity underutilized when the cooling power is below its peak, particularly in cooler months. On the other hand, sizing the compute system aggressively based on low cooling power can cause the total site-level power demand to exceed the site-level power capacity during hot days in the summer. This paper proposes ComputeAmp (Compute Amplifier), a framework that maximizes the compute capacity by jointly and dynamically leveraging cooling, battery energy storage, and computing-based adaptation. We discuss the opportunities and limitations of ComputeAmp and illustrate its potential to significantly expand usable compute capacity within local power and water resource limits. We also present a problem formulation for ComputeAmp and highlight a few algorithmic and operational challenges.

arXivPreprint
Read the paper & insight

AI & modeling/ Related research

Pushing the Frontiers for Floating Solar Photovoltaics -- The Case for South America

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

arXivPreprint

Resources & environment/ Related research

AI Data Centers and the Water Use Feedback Loop

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

arXivPreprint

READING NOTEStart with the research insight, then examine the methods, comparisons and conditions.

RESEARCH & PERSPECTIVES

Papers & insights

Leave each paper with a question worth pursuing.

8 papers

Cooling & thermal management

01

Maximizing Compute Capacity in AI Data Centers through Cooling, Energy Storage, and Computing Adaptation

arXivPreprint
Research overview

The deployment of artificial intelligence is increasingly constrained by limited site-level power capacity, which must support both compute systems and non-compute systems (primarily cooling) at all times. Cooling power demand, especially in non-evaporative cooling systems, can increase substantially with ambient temperature in the summer, producing recurring periods of elevated cooling power that often lasts for multiple hours per day. Therefore, maximizing compute capacity under a limited site-level power budget is an important planning and operational challenge. Sizing the compute system conservatively based on peak cooling power can leave part of the site-level power capacity underutilized when the cooling power is below its peak, particularly in cooler months. On the other hand, sizing the compute system aggressively based on low cooling power can cause the total site-level power demand to exceed the site-level power capacity during hot days in the summer. This paper proposes ComputeAmp (Compute Amplifier), a framework that maximizes the compute capacity by jointly and dynamically leveraging cooling, battery energy storage, and computing-based adaptation. We discuss the opportunities and limitations of ComputeAmp and illustrate its potential to significantly expand usable compute capacity within local power and water resource limits. We also present a problem formulation for ComputeAmp and highlight a few algorithmic and operational challenges.

Abstract & detailed commentary

Shaolei Ren, Mohammad A. Islam, Adam Wierman

Chinese abstract

The deployment of artificial intelligence is increasingly constrained by limited site-level power capacity, which must support both compute systems and non-compute systems (primarily cooling) at all times. Cooling power demand, especially in non-evaporative cooling systems, can increase substantially with ambient temperature in the summer, producing recurring periods of elevated cooling power that often lasts for multiple hours per day. Therefore, maximizing compute capacity under a limited site-level power budget is an important planning and operational challenge. Sizing the compute system conservatively based on peak cooling power can leave part of the site-level power capacity underutilized when the cooling power is below its peak, particularly in cooler months. On the other hand, sizing the compute system aggressively based on low cooling power can cause the total site-level power demand to exceed the site-level power capacity during hot days in the summer. This paper proposes ComputeAmp (Compute Amplifier), a framework that maximizes the compute capacity by jointly and dynamically leveraging cooling, battery energy storage, and computing-based adaptation. We discuss the opportunities and limitations of ComputeAmp and illustrate its potential to significantly expand usable compute capacity within local power and water resource limits. We also present a problem formulation for ComputeAmp and highlight a few algorithmic and operational challenges.

Original paperChinese poster

AI & modeling

02

Pushing the Frontiers for Floating Solar Photovoltaics -- The Case for South America

arXivPreprint
Research overview

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Abstract & detailed commentary

Soham Ghosh, Anik Goswami, Krishna Kumba

Chinese abstract

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Original paperChinese poster

AI & modeling

03

Learning Burst-Aware Early Warning Models for Capacity Stress under AI Workload Surges in Hyperscale Data Centers

arXivPreprint
Research overview

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mechanisms. In this paper, we propose a deployment-oriented, burst-aware early warning framework for proactive capacity stress prediction under AI workload surges. We formulate the problem as a high-recall forecasting task over multivariate telemetry windows, with the explicit goal of enabling operational intervention before system degradation occurs. The proposed framework integrates workload intensity, temporal variation, and system pressure signals, and employs a lightweight tree-based learning model to capture nonlinear interactions in highly imbalanced environments. To evaluate the system under realistic conditions, we introduce an AI workload surge injection methodology that simulates burst-driven demand patterns observed in large-scale AI systems. Our XGBoost-based model achieves an ROC AUC of 0.697 and an AP of 0.670, significantly outperforming baseline methods. Under deployment-oriented threshold selection, the framework achieves a Recall of 0.914, enabling the detection of the majority of stress-prone periods with acceptable false-alarm cost. Beyond predictive performance, we show how the proposed framework can be integrated into operational control loops to support proactive actions such as workload throttling and resource scaling. Our results highlight the practical value of high-recall, learning-based early warning systems in enabling resilient and adaptive data center operations in the era of AI-driven workloads.

Abstract & detailed commentary

Zihan Yu, Xianling Zeng, Zhiming Xue, Yalun Qi, Sichen Zhao

Chinese abstract

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mechanisms. In this paper, we propose a deployment-oriented, burst-aware early warning framework for proactive capacity stress prediction under AI workload surges. We formulate the problem as a high-recall forecasting task over multivariate telemetry windows, with the explicit goal of enabling operational intervention before system degradation occurs. The proposed framework integrates workload intensity, temporal variation, and system pressure signals, and employs a lightweight tree-based learning model to capture nonlinear interactions in highly imbalanced environments. To evaluate the system under realistic conditions, we introduce an AI workload surge injection methodology that simulates burst-driven demand patterns observed in large-scale AI systems. Our XGBoost-based model achieves an ROC AUC of 0.697 and an AP of 0.670, significantly outperforming baseline methods. Under deployment-oriented threshold selection, the framework achieves a Recall of 0.914, enabling the detection of the majority of stress-prone periods with acceptable false-alarm cost. Beyond predictive performance, we show how the proposed framework can be integrated into operational control loops to support proactive actions such as workload throttling and resource scaling. Our results highlight the practical value of high-recall, learning-based early warning systems in enabling resilient and adaptive data center operations in the era of AI-driven workloads.

Original paperChinese poster

AI & modeling

04

Node-Level Performance and Energy Characterization of Flagship Science Applications on SuperMUC-NG Phase 2

arXivPreprint
Research overview

We present a systematic performance and energy-efficiency characterization of five flagship scientific workloads on SuperMUC-NG phase 2, the 28 PetaFLOPs system at the Leibniz Supercomputing Center (LRZ) equipped with Intel Xeon Platinum 8480+ and Intel Data Center GPU Max 1550 (Ponte Vecchio, PVC) accelerators. The selected codes span molecular dynamics (gromacs, lammps), astrophysics and cosmology (OpenGadget3, AthenaK), and finite-element PDE solvers from the dealii-X Center of Excellence. For each code we measure throughput and energy efficiency expressed as compute-elements per wall-clock second (or per Joule of consumed energy) on a single compute node, comparing CPU-only (SPR) against combined CPU+GPU (SPR+PVC) configurations where available. Energy measurements rely on lightweight code instrumentation with p3em, or the Energy Aware Runtime (EAR) present on the system. Our results show that GPU offload yields $4-12\times$ higher throughput and up to $15\times$ better energy efficiency compared to CPU-only execution, with lammps and AthenaK benefiting most. However, both throughput and energy gains are sensitive to problem granularity: insufficient work per GPU tile erodes the accelerator advantage, as clearly observed in AthenaK at small mesh-block sizes. The power-budget utilization is systematically lower for CPUs than it is for GPUs, indicating that even at peak useful-work rate, most applications running on CPUs leave a significant fraction of the node's thermal envelope unused.

Abstract & detailed commentary

Salvatore Cielo, Elmira Birang, Alexander Pöppl, Sajad Azizi, Plamen Dobrev, Margarita Egelhofer, Ivan Pribec, Gerald Mathias

Chinese abstract

We present a systematic performance and energy-efficiency characterization of five flagship scientific workloads on SuperMUC-NG phase 2, the 28 PetaFLOPs system at the Leibniz Supercomputing Center (LRZ) equipped with Intel Xeon Platinum 8480+ and Intel Data Center GPU Max 1550 (Ponte Vecchio, PVC) accelerators. The selected codes span molecular dynamics (gromacs, lammps), astrophysics and cosmology (OpenGadget3, AthenaK), and finite-element PDE solvers from the dealii-X Center of Excellence. For each code we measure throughput and energy efficiency expressed as compute-elements per wall-clock second (or per Joule of consumed energy) on a single compute node, comparing CPU-only (SPR) against combined CPU+GPU (SPR+PVC) configurations where available. Energy measurements rely on lightweight code instrumentation with p3em, or the Energy Aware Runtime (EAR) present on the system. Our results show that GPU offload yields $4-12\times$ higher throughput and up to $15\times$ better energy efficiency compared to CPU-only execution, with lammps and AthenaK benefiting most. However, both throughput and energy gains are sensitive to problem granularity: insufficient work per GPU tile erodes the accelerator advantage, as clearly observed in AthenaK at small mesh-block sizes. The power-budget utilization is systematically lower for CPUs than it is for GPUs, indicating that even at peak useful-work rate, most applications running on CPUs leave a significant fraction of the node's thermal envelope unused.

Original paperChinese poster

Resources & environment

05

AI Data Centers and the Water Use Feedback Loop

arXivPreprint
Research overview

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

Abstract & detailed commentary

Basit A. Akinade, Amobichukwu C. Amanambu, Jonathan M. Frame, Shaolei Ren

Chinese abstract

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

Original paperChinese poster

Cooling & thermal management

06

Revisiting "Cooler is Better": ITD-Aware Per-CPU Thermal Optimization for Sustainable Data Center Operation

arXivPreprint
Research overview

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

Abstract & detailed commentary

Jason Crop, Hayden Moore, Sudeep Pasricha

Chinese abstract

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

Original paperChinese poster

Compute–power coordination

07

AI Data Centers and Power System Sustainability: Understanding the Sustainability Implications of AI-Driven Data Centers on Power Systems

arXivPreprint
Research overview

The rapid expansion of artificial intelligence (AI) has driven unprecedented growth in data center electricity demand. The scale and pace of this load growth carry significant implications for the sustainability of electric power systems. On the one hand, rapid, spatially concentrated data center load growth is outpacing clean energy deployment in several major regions, raising emissions and challenging both grid flexibility and reliability. On the other hand, this fast-developing and capital-intensive sector offers abundant opportunities to advance sustainability through clean energy integration and operational innovations. This article provides an overview of the mechanisms through which data center affect power system sustainability, underscoring both risks and the potential. Specifically, this article (i) characterizes AI data center load behavior and categorizes electricity supply configurations by function and sustainability profile, as well as situates these loads within global and regional electricity demand trends; (ii) analyzes sustainability impacts across short-run operational and long-run planning mechanisms, evaluates effects on grid carbon emissions and renewable energy utilization, and feasibility of offering system flexibility and participating in ancillary service; and (iii) evaluates real-world corporate sustainability pathways and highlighting both the system benefits and feasibility limits of current carbon accounting practices. The goal of this work is to synthesize existing knowledge and technological developments and to guide research and development toward a more sustainable integration of AI data centers and electric power systems.

Abstract & detailed commentary

Yuhao Huang, Novarun Deb, Hamidreza Zareipour

Chinese abstract

The rapid expansion of artificial intelligence (AI) has driven unprecedented growth in data center electricity demand. The scale and pace of this load growth carry significant implications for the sustainability of electric power systems. On the one hand, rapid, spatially concentrated data center load growth is outpacing clean energy deployment in several major regions, raising emissions and challenging both grid flexibility and reliability. On the other hand, this fast-developing and capital-intensive sector offers abundant opportunities to advance sustainability through clean energy integration and operational innovations. This article provides an overview of the mechanisms through which data center affect power system sustainability, underscoring both risks and the potential. Specifically, this article (i) characterizes AI data center load behavior and categorizes electricity supply configurations by function and sustainability profile, as well as situates these loads within global and regional electricity demand trends; (ii) analyzes sustainability impacts across short-run operational and long-run planning mechanisms, evaluates effects on grid carbon emissions and renewable energy utilization, and feasibility of offering system flexibility and participating in ancillary service; and (iii) evaluates real-world corporate sustainability pathways and highlighting both the system benefits and feasibility limits of current carbon accounting practices. The goal of this work is to synthesize existing knowledge and technological developments and to guide research and development toward a more sustainable integration of AI data centers and electric power systems.

Original paperChinese poster

Computing & systems

08

From Tokens to Energy Flexibility: Quantization-Enabled Demand Response for Data Centers with LLM Inference Workloads

arXivPreprint
Research overview

The rapid growth of large language model (LLM) inference is creating significant data-center loads that face increasing energy-management challenges under tightening grid conditions and demand response (DR) requirements. Conventional data-center energy management mainly relies on temporal and spatial workload shifting and campus-level energy asset scheduling, but it usually treats LLM inference demand as an aggregate load. As a result, these approaches fail to exploit the internal characteristics of LLM serving and therefore overlook the flexibility offered by LLM-specific techniques such as model quantization. To unlock this flexibility, this paper proposes a quantization-enabled energy management framework for grid-responsive LLM inference data centers. First, a quantization-to-power model is established to map each model--quantization configuration to a compact set of dispatchable parameters. Second, a two-stage quantization-enabled DR model is developed to account for model instance switching, request routing, and precision selection. Third, a multi-campus co-optimization method is introduced for DR participation by integrating grid-side electricity and carbon signals with the quantization-enabled DR model. Case studies show that the proposed framework reduces total data-center operating cost by 34.3\% without curtailing served token volume, validating model quantization as an effective flexibility lever for grid-responsive LLM data-center energy management.

Abstract & detailed commentary

Bojun Du, Xiaoyi Fan, Ershun Du, Long Chen, Jianpei Han, Qingchun Hou, Ning Zhang, Chongqing Kang

Chinese abstract

The rapid growth of large language model (LLM) inference is creating significant data-center loads that face increasing energy-management challenges under tightening grid conditions and demand response (DR) requirements. Conventional data-center energy management mainly relies on temporal and spatial workload shifting and campus-level energy asset scheduling, but it usually treats LLM inference demand as an aggregate load. As a result, these approaches fail to exploit the internal characteristics of LLM serving and therefore overlook the flexibility offered by LLM-specific techniques such as model quantization. To unlock this flexibility, this paper proposes a quantization-enabled energy management framework for grid-responsive LLM inference data centers. First, a quantization-to-power model is established to map each model--quantization configuration to a compact set of dispatchable parameters. Second, a two-stage quantization-enabled DR model is developed to account for model instance switching, request routing, and precision selection. Third, a multi-campus co-optimization method is introduced for DR participation by integrating grid-side electricity and carbon signals with the quantization-enabled DR model. Case studies show that the proposed framework reduces total data-center operating cost by 34.3\% without curtailing served token volume, validating model quantization as an effective flexibility lever for grid-responsive LLM data-center energy management.

Original paperChinese poster