Research Article算电协同

Revisiting "Cooler is Better": ITD-Aware Per-CPU Thermal Optimization for Sustainable Data Center Operation

Jason Crop、Hayden Moore、Sudeep Pasricha

Published 2026-06-10 · arXiv · Credibility S

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic p…

Abstract, interpretation and reference

Abstract

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Jason Crop, Hayden Moore, Sudeep Pasricha. Revisiting "Cooler is Better": ITD-Aware Per-CPU Thermal Optimization for Sustainable Data Center Operation[J/OL]. (2026-06-10)[2026-06-26]. http://arxiv.org/abs/2606.11163v1.

Full text 中文海报
算电协同 论文图示
Research ArticleAI 运维优化

Hot AI in Cold Space: Thermal-Crosstalk-Aware Scheduling for Sustainable Orbital AI Clusters

Shuyi Chen、Zhengchang Hua、Nikos Tziritas、Georgios Theodoropoulos

Published 2026-06-23 · arXiv · Credibility S

Terrestrial AI training faces an unsustainable energy and water crisis, positioning Orbital Data Centers (ODCs) as a "zero operational carbon" alternative. However, the sub-$10μ\text{s}$ communication latency required for distributed Large Language Model (LLM) training forces ODCs into extreme physical density, triggering a critical "Proximity-Thermal Paradox." As these high-density systems scale into Monolithic Str…

Abstract, interpretation and reference

Abstract

Terrestrial AI training faces an unsustainable energy and water crisis, positioning Orbital Data Centers (ODCs) as a "zero operational carbon" alternative. However, the sub-$10μ\text{s}$ communication latency required for distributed Large Language Model (LLM) training forces ODCs into extreme physical density, triggering a critical "Proximity-Thermal Paradox." As these high-density systems scale into Monolithic Structures or Proximity Swarms, they suffer from intense thermal-fluid crosstalk (heat traps in shared cooling loops) and thermal-radiative crosstalk (mutual heating that blocks deep-space cooling radiators). If left unmitigated, this persistent heat stagnation not only triggers severe thermal throttling that degrades training throughput, but also induces severe thermal fatigue, drastically shortening hardware lifespans and generating premature space e-waste. To make orbital AI truly sustainable, this position paper challenges traditional uniform load-sharing. We propose the Thermal-Aware Heterogeneity Thesis, which treats spatial cooling variances as a primary resource management dimension. Building on this, we introduce Thermal-Load Balancing (TLB), a software framework that dynamically migrates LLM workloads to the coolest available units based on instantaneous fluid temperatures or absorbed radiation. Our analysis demonstrates that TLB resolves thermal bottlenecks to restore Model Flops Utilization (MFU), while simultaneously reducing physical thermal stress. Extending the operational lifespan of orbital hardware is crucial to amortize the massive embodied carbon of rocket launches, outlining a necessary pathway to scale orbital AI without accelerating e-waste.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,AI 运维、负载预测和设施调优正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断AI 工具是否能降低运维复杂度并提升可用性。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Shuyi Chen, Zhengchang Hua, Nikos Tziritas, 等. Hot AI in Cold Space: Thermal-Crosstalk-Aware Scheduling for Sustainable Orbital AI Clusters[J/OL]. (2026-06-23)[2026-06-26]. http://arxiv.org/abs/2606.26150v1.

Full text 中文海报
AI 运维优化 论文图示
Research Article热管理与液冷

Toward Next-Generation AI Data Centers: Power Delivery Architecture Shifts, Emerging Technologies, and Challenges

Sangwhee Lee、Rafal P. Wojda、Cheol-Hee Jo、Shuntaro Inoue、Pedro Ribeiro、Gui-Jia Su、Mostak Mohammad、Himel Barua

Published 2026-06-24 · arXiv · Credibility S

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enab…

Abstract, interpretation and reference

Abstract

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enabling technological building blocks: high-voltage conversion-ratio DC/DC converters, facility-level low-voltage DC distribution, and medium-voltage solid-state transformers. The advantages, technical challenges, and potential solutions associated with each building block are reviewed. Finally, future research directions and open challenges are discussed.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用综述归纳和指标比较,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向跨地域数据中心负载与电力资源之间的调度关系。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Sangwhee Lee, Rafal P. Wojda, Cheol-Hee Jo, 等. Toward Next-Generation AI Data Centers: Power Delivery Architecture Shifts, Emerging Technologies, and Challenges[J/OL]. (2026-06-24)[2026-06-26]. http://arxiv.org/abs/2606.25095v1.

Full text 中文海报
热管理与液冷 论文图示
Research Article算电协同

A Bilevel Framework for Data Center-Grid Coordination with DLMPs in Unbalanced Three-Phase Distribution Systems

Arash Baharvandi、Duong Tung Nguyen

Published 2026-06-25 · arXiv · Credibility S

This paper proposes a grid-aware coordination framework between data centers and distribution grids using a DLMP-based bilevel optimization model. The data center aggregator (DCA) determines active power demand in response to distribution locational marginal prices (DLMPs), while the distribution system operator (DSO) solves a network-constrained optimal power flow problem to determine DLMPs in an unbalanced three-p…

Abstract, interpretation and reference

Abstract

This paper proposes a grid-aware coordination framework between data centers and distribution grids using a DLMP-based bilevel optimization model. The data center aggregator (DCA) determines active power demand in response to distribution locational marginal prices (DLMPs), while the distribution system operator (DSO) solves a network-constrained optimal power flow problem to determine DLMPs in an unbalanced three-phase system. The model incorporates both active and reactive power consumption of data centers to evaluate their impacts on voltage regulation and phase imbalance. To mitigate adverse network effects, two operating cases are analyzed: without reactive power compensation and with static var generator (SVG)-based compensation. The proposed approach is validated on the IEEE 37-bus unbalanced distribution test system. Simulation results show that DLMP-based coordination captures economically efficient data center operation, and phase- and location-dependent network conditions, while SVG-based compensation improves voltage profiles and reduces phase unbalance.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Arash Baharvandi, Duong Tung Nguyen. A Bilevel Framework for Data Center-Grid Coordination with DLMPs in Unbalanced Three-Phase Distribution Systems[J/OL]. (2026-06-25)[2026-06-26]. http://arxiv.org/abs/2606.26328v1.

Full text 中文海报
算电协同 论文图示
Research ArticleAI 运维优化

Learning Burst-Aware Early Warning Models for Capacity Stress under AI Workload Surges in Hyperscale Data Centers

Zihan Yu、Xianling Zeng、Zhiming Xue、Yalun Qi、Sichen Zhao

Published 2026-06-19 · arXiv · Credibility S

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mech…

Abstract, interpretation and reference

Abstract

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mechanisms. In this paper, we propose a deployment-oriented, burst-aware early warning framework for proactive capacity stress prediction under AI workload surges. We formulate the problem as a high-recall forecasting task over multivariate telemetry windows, with the explicit goal of enabling operational intervention before system degradation occurs. The proposed framework integrates workload intensity, temporal variation, and system pressure signals, and employs a lightweight tree-based learning model to capture nonlinear interactions in highly imbalanced environments. To evaluate the system under realistic conditions, we introduce an AI workload surge injection methodology that simulates burst-driven demand patterns observed in large-scale AI systems. Our XGBoost-based model achieves an ROC AUC of 0.697 and an AP of 0.670, significantly outperforming baseline methods. Under deployment-oriented threshold selection, the framework achieves a Recall of 0.914, enabling the detection of the majority of stress-prone periods with acceptable false-alarm cost. Beyond predictive performance, we show how the proposed framework can be integrated into operational control loops to support proactive actions such as workload throttling and resource scaling. Our results highlight the practical value of high-recall, learning-based early warning systems in enabling resilient and adaptive data center operations in the era of AI-driven workloads.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,AI 运维、负载预测和设施调优正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用框架构建和频域/系统级分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向跨地域数据中心负载与电力资源之间的调度关系。意义:对日报读者而言,它可用于判断AI 工具是否能降低运维复杂度并提升可用性。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Zihan Yu, Xianling Zeng, Zhiming Xue, 等. Learning Burst-Aware Early Warning Models for Capacity Stress under AI Workload Surges in Hyperscale Data Centers[J/OL]. (2026-06-19)[2026-06-26]. http://arxiv.org/abs/2606.21130v1.

Full text 中文海报
AI 运维优化 论文图示
Research Article热管理与液冷

AI Data Centers and the Water Use Feedback Loop

Basit A. Akinade、Amobichukwu C. Amanambu、Jonathan M. Frame、Shaolei Ren

Published 2026-06-20 · arXiv · Credibility S

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, f…

Abstract, interpretation and reference

Abstract

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用综述归纳和指标比较,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向冷却效率、能源利用或运维策略的改进方向。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Basit A. Akinade, Amobichukwu C. Amanambu, Jonathan M. Frame, 等. AI Data Centers and the Water Use Feedback Loop[J/OL]. (2026-06-20)[2026-06-26]. http://arxiv.org/abs/2606.21760v1.

Full text 中文海报
热管理与液冷 论文图示
Research Article算电协同

Power-Flexible AI Data Centers: A New Paradigm for Grid-Responsive Compute

Chris Williams、Philip Colangelo、Ayse Coskun、Ethan Levine、Andy Neale、Ciaran Roberts、Shayan Sengupta、Nikhil Shirolkar

Published 2026-06-24 · arXiv · Credibility S

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through s…

Abstract, interpretation and reference

Abstract

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。

参考文献

Chris Williams, Philip Colangelo, Ayse Coskun, 等. Power-Flexible AI Data Centers: A New Paradigm for Grid-Responsive Compute[J/OL]. (2026-06-24)[2026-06-26]. http://arxiv.org/abs/2606.25098v1.

Full text 中文海报
算电协同 论文图示
Research Article算电协同

GaN Power Devices and Converter Architectures for AI Data Centers: Efficiency, Reliability, and Deployment Pathways

Donald Intal、Abasifreke Ebong

Published 2026-06-24 · arXiv · Credibility S

The growth of artificial-intelligence workloads is increasing the electrical and thermal demands on data-center power-delivery systems, making conversion efficiency, power density, and reliability critical design priorities. This review examines how gallium-nitride (GaN) power devices can be matched to specific stages of the grid-to-load conversion chain, including power-factor correction, isolated DC/DC conversion,…

Abstract, interpretation and reference

Abstract

The growth of artificial-intelligence workloads is increasing the electrical and thermal demands on data-center power-delivery systems, making conversion efficiency, power density, and reliability critical design priorities. This review examines how gallium-nitride (GaN) power devices can be matched to specific stages of the grid-to-load conversion chain, including power-factor correction, isolated DC/DC conversion, 48-V intermediate-bus conversion, and point-of-load regulation. Si, SiC, and GaN are compared using converter-relevant metrics, and lateral, vertical, and specialized GaN architectures are evaluated in terms of voltage scalability, switching behavior, reverse conduction, thermal pathways, gate control, and technology maturity. The analysis shows that GaN provides a stage-dependent rather than universal advantage. Commercial lateral GaN HEMTs are particularly effective in high-frequency, low-to-mid-voltage stages, while specialized and hybrid devices support bidirectional operation, normally-off control, extreme conversion ratios, and integration. Vertical GaN remains an emerging option for higher-voltage and higher-power conversion. A quantitative framework links cascaded converter efficiency to electrical-loss reduction, cooling demand, annual facility energy use, and operational carbon emissions. Broad deployment further requires low-parasitic packaging, disciplined gate-drive and EMI co-design, mission-profile reliability qualification, scalable manufacturing, and supply-chain resilience. GaN is therefore best treated as a stage-specific system lever whose value depends on coordinated device, topology, package, and thermal co-design.

中文解读

背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用综述归纳和指标比较,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。