bupt.ai Research & perspectives

AIDC RESEARCH

Computing Research Frontiers.

Research connecting computing, power and thermal management

DAILY RESEARCH EDITIONCooling · Compute–power coordination · AI infrastructure

In focus/ Research highlights

8 papers4 research areas

Cooling & thermal management/ In focus

Hot AI in Cold Space: Thermal-Crosstalk-Aware Scheduling for Sustainable Orbital AI Clusters

Terrestrial AI training faces an unsustainable energy and water crisis, positioning Orbital Data Centers (ODCs) as a "zero operational carbon" alternative. However, the sub-$10μ\text{s}$ communication latency required for synchronized scientific workloads, such as distributed Large Language Model (LLM) training, forces ODCs into extreme physical density, triggering a critical "Proximity-Thermal Paradox." As these high-density systems scale into Monolithic Structures or Proximity Swarms, they suffer from intense thermal-fluid crosstalk (heat traps in shared cooling loops) and thermal-radiative crosstalk (mutual heating that blocks deep-space cooling radiators). If left unmitigated, this persistent heat stagnation not only triggers severe thermal throttling that degrades training throughput, but also induces severe thermal fatigue, drastically shortening hardware lifespans and generating premature space e-waste. To make orbital AI truly sustainable, this position paper challenges traditional uniform load-sharing. We propose the Thermal-Aware Heterogeneity Thesis, which treats spatial cooling variances as a primary resource management dimension. Building on this, we introduce Thermal-Load Balancing (TLB), a software framework that dynamically migrates these intensive workloads to the coolest available units based on instantaneous fluid temperatures or absorbed radiation. Our analysis demonstrates that TLB resolves thermal bottlenecks to restore Model Flops Utilization (MFU), while simultaneously reducing physical thermal stress. Extending the operational lifespan of orbital hardware is crucial to amortize the massive embodied carbon of rocket launches, outlining a necessary pathway to scale orbital AI without accelerating e-waste.

arXivPreprint
Read the paper & insight

Compute–power coordination/ Related research

A Bilevel Framework for Data Center-Grid Coordination with DLMPs in Unbalanced Three-Phase Distribution Systems

This paper proposes a grid-aware coordination framework between data centers and distribution grids using a DLMP-based bilevel optimization model. The data center aggregator (DCA) determines active power demand in response to distribution locational marginal prices (DLMPs), while the distribution system operator (DSO) solves a network-constrained optimal power flow problem to determine DLMPs in an unbalanced three-phase system. The model incorporates both active and reactive power consumption of data centers to evaluate their impacts on voltage regulation and phase imbalance. To mitigate adverse network effects, two operating cases are analyzed: without reactive power compensation and with static var generator (SVG)-based compensation. The proposed approach is validated on the IEEE 37-bus unbalanced distribution test system. Simulation results show that DLMP-based coordination captures economically efficient data center operation, and phase- and location-dependent network conditions, while SVG-based compensation improves voltage profiles and reduces phase unbalance.

arXivPreprint

AI & modeling/ Related research

Node-Level Performance and Energy Characterization of Flagship Science Applications on SuperMUC-NG Phase 2

We present a systematic performance and energy-efficiency characterization of five flagship scientific workloads on SuperMUC-NG phase 2, the 28 PetaFLOPs system at the Leibniz Supercomputing Center (LRZ) equipped with Intel Xeon Platinum 8480+ and Intel Data Center GPU Max 1550 (Ponte Vecchio, PVC) accelerators. The selected codes span molecular dynamics (gromacs, lammps), astrophysics and cosmology (OpenGadget3, AthenaK), and finite-element PDE solvers from the dealii-X Center of Excellence. For each code we measure throughput and energy efficiency expressed as compute-elements per wall-clock second (or per Joule of consumed energy) on a single compute node, comparing CPU-only (SPR) against combined CPU+GPU (SPR+PVC) configurations where available. Energy measurements rely on lightweight code instrumentation with p3em, or the Energy Aware Runtime (EAR) present on the system. Our results show that GPU offload yields $4-12\times$ higher throughput and up to $15\times$ better energy efficiency compared to CPU-only execution, with lammps and AthenaK benefiting most. However, both throughput and energy gains are sensitive to problem granularity: insufficient work per GPU tile erodes the accelerator advantage, as clearly observed in AthenaK at small mesh-block sizes. The power-budget utilization is systematically lower for CPUs than it is for GPUs, indicating that even at peak useful-work rate, most applications running on CPUs leave a significant fraction of the node's thermal envelope unused.

arXivPreprint

READING NOTEStart with the research insight, then examine the methods, comparisons and conditions.

RESEARCH & PERSPECTIVES

Papers & insights

Leave each paper with a question worth pursuing.

8 papers

Compute–power coordination

01

A Bilevel Framework for Data Center-Grid Coordination with DLMPs in Unbalanced Three-Phase Distribution Systems

arXivPreprint
Research overview

This paper proposes a grid-aware coordination framework between data centers and distribution grids using a DLMP-based bilevel optimization model. The data center aggregator (DCA) determines active power demand in response to distribution locational marginal prices (DLMPs), while the distribution system operator (DSO) solves a network-constrained optimal power flow problem to determine DLMPs in an unbalanced three-phase system. The model incorporates both active and reactive power consumption of data centers to evaluate their impacts on voltage regulation and phase imbalance. To mitigate adverse network effects, two operating cases are analyzed: without reactive power compensation and with static var generator (SVG)-based compensation. The proposed approach is validated on the IEEE 37-bus unbalanced distribution test system. Simulation results show that DLMP-based coordination captures economically efficient data center operation, and phase- and location-dependent network conditions, while SVG-based compensation improves voltage profiles and reduces phase unbalance.

Abstract & detailed commentary

Arash Baharvandi, Duong Tung Nguyen

Chinese abstract

This paper proposes a grid-aware coordination framework between data centers and distribution grids using a DLMP-based bilevel optimization model. The data center aggregator (DCA) determines active power demand in response to distribution locational marginal prices (DLMPs), while the distribution system operator (DSO) solves a network-constrained optimal power flow problem to determine DLMPs in an unbalanced three-phase system. The model incorporates both active and reactive power consumption of data centers to evaluate their impacts on voltage regulation and phase imbalance. To mitigate adverse network effects, two operating cases are analyzed: without reactive power compensation and with static var generator (SVG)-based compensation. The proposed approach is validated on the IEEE 37-bus unbalanced distribution test system. Simulation results show that DLMP-based coordination captures economically efficient data center operation, and phase- and location-dependent network conditions, while SVG-based compensation improves voltage profiles and reduces phase unbalance.

Original paperChinese poster

AI & modeling

02

Node-Level Performance and Energy Characterization of Flagship Science Applications on SuperMUC-NG Phase 2

arXivPreprint
Research overview

We present a systematic performance and energy-efficiency characterization of five flagship scientific workloads on SuperMUC-NG phase 2, the 28 PetaFLOPs system at the Leibniz Supercomputing Center (LRZ) equipped with Intel Xeon Platinum 8480+ and Intel Data Center GPU Max 1550 (Ponte Vecchio, PVC) accelerators. The selected codes span molecular dynamics (gromacs, lammps), astrophysics and cosmology (OpenGadget3, AthenaK), and finite-element PDE solvers from the dealii-X Center of Excellence. For each code we measure throughput and energy efficiency expressed as compute-elements per wall-clock second (or per Joule of consumed energy) on a single compute node, comparing CPU-only (SPR) against combined CPU+GPU (SPR+PVC) configurations where available. Energy measurements rely on lightweight code instrumentation with p3em, or the Energy Aware Runtime (EAR) present on the system. Our results show that GPU offload yields $4-12\times$ higher throughput and up to $15\times$ better energy efficiency compared to CPU-only execution, with lammps and AthenaK benefiting most. However, both throughput and energy gains are sensitive to problem granularity: insufficient work per GPU tile erodes the accelerator advantage, as clearly observed in AthenaK at small mesh-block sizes. The power-budget utilization is systematically lower for CPUs than it is for GPUs, indicating that even at peak useful-work rate, most applications running on CPUs leave a significant fraction of the node's thermal envelope unused.

Abstract & detailed commentary

Salvatore Cielo, Elmira Birang, Alexander Pöppl, Sajad Azizi, Plamen Dobrev, Margarita Egelhofer, Ivan Pribec, Gerald Mathias

Chinese abstract

We present a systematic performance and energy-efficiency characterization of five flagship scientific workloads on SuperMUC-NG phase 2, the 28 PetaFLOPs system at the Leibniz Supercomputing Center (LRZ) equipped with Intel Xeon Platinum 8480+ and Intel Data Center GPU Max 1550 (Ponte Vecchio, PVC) accelerators. The selected codes span molecular dynamics (gromacs, lammps), astrophysics and cosmology (OpenGadget3, AthenaK), and finite-element PDE solvers from the dealii-X Center of Excellence. For each code we measure throughput and energy efficiency expressed as compute-elements per wall-clock second (or per Joule of consumed energy) on a single compute node, comparing CPU-only (SPR) against combined CPU+GPU (SPR+PVC) configurations where available. Energy measurements rely on lightweight code instrumentation with p3em, or the Energy Aware Runtime (EAR) present on the system. Our results show that GPU offload yields $4-12\times$ higher throughput and up to $15\times$ better energy efficiency compared to CPU-only execution, with lammps and AthenaK benefiting most. However, both throughput and energy gains are sensitive to problem granularity: insufficient work per GPU tile erodes the accelerator advantage, as clearly observed in AthenaK at small mesh-block sizes. The power-budget utilization is systematically lower for CPUs than it is for GPUs, indicating that even at peak useful-work rate, most applications running on CPUs leave a significant fraction of the node's thermal envelope unused.

Original paperChinese poster

Resources & environment

03

AI Data Centers and the Water Use Feedback Loop

arXivPreprint
Research overview

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

Abstract & detailed commentary

Basit A. Akinade, Amobichukwu C. Amanambu, Jonathan M. Frame, Shaolei Ren

Chinese abstract

AI data centres consume water for cooling, water scarcity constrains siting, and AI tools can improve water system efficiency. These dynamics are studied separately yet form a feedback loop. This review formalises the Water and AI Feedback Loop, introduces the Water Consumption Impact index to quantify community-scale utility burden, and demonstrates across ten US sites that burden spans three orders of magnitude, from 0.2% to 134% of host capacity.

Original paperChinese poster

Cooling & thermal management

04

Hot AI in Cold Space: Thermal-Crosstalk-Aware Scheduling for Sustainable Orbital AI Clusters

arXivPreprint
Research overview

Terrestrial AI training faces an unsustainable energy and water crisis, positioning Orbital Data Centers (ODCs) as a "zero operational carbon" alternative. However, the sub-$10μ\text{s}$ communication latency required for synchronized scientific workloads, such as distributed Large Language Model (LLM) training, forces ODCs into extreme physical density, triggering a critical "Proximity-Thermal Paradox." As these high-density systems scale into Monolithic Structures or Proximity Swarms, they suffer from intense thermal-fluid crosstalk (heat traps in shared cooling loops) and thermal-radiative crosstalk (mutual heating that blocks deep-space cooling radiators). If left unmitigated, this persistent heat stagnation not only triggers severe thermal throttling that degrades training throughput, but also induces severe thermal fatigue, drastically shortening hardware lifespans and generating premature space e-waste. To make orbital AI truly sustainable, this position paper challenges traditional uniform load-sharing. We propose the Thermal-Aware Heterogeneity Thesis, which treats spatial cooling variances as a primary resource management dimension. Building on this, we introduce Thermal-Load Balancing (TLB), a software framework that dynamically migrates these intensive workloads to the coolest available units based on instantaneous fluid temperatures or absorbed radiation. Our analysis demonstrates that TLB resolves thermal bottlenecks to restore Model Flops Utilization (MFU), while simultaneously reducing physical thermal stress. Extending the operational lifespan of orbital hardware is crucial to amortize the massive embodied carbon of rocket launches, outlining a necessary pathway to scale orbital AI without accelerating e-waste.

Abstract & detailed commentary

Shuyi Chen, Zhengchang Hua, Nikos Tziritas, Georgios Theodoropoulos

Chinese abstract

Terrestrial AI training faces an unsustainable energy and water crisis, positioning Orbital Data Centers (ODCs) as a "zero operational carbon" alternative. However, the sub-$10μ\text{s}$ communication latency required for synchronized scientific workloads, such as distributed Large Language Model (LLM) training, forces ODCs into extreme physical density, triggering a critical "Proximity-Thermal Paradox." As these high-density systems scale into Monolithic Structures or Proximity Swarms, they suffer from intense thermal-fluid crosstalk (heat traps in shared cooling loops) and thermal-radiative crosstalk (mutual heating that blocks deep-space cooling radiators). If left unmitigated, this persistent heat stagnation not only triggers severe thermal throttling that degrades training throughput, but also induces severe thermal fatigue, drastically shortening hardware lifespans and generating premature space e-waste. To make orbital AI truly sustainable, this position paper challenges traditional uniform load-sharing. We propose the Thermal-Aware Heterogeneity Thesis, which treats spatial cooling variances as a primary resource management dimension. Building on this, we introduce Thermal-Load Balancing (TLB), a software framework that dynamically migrates these intensive workloads to the coolest available units based on instantaneous fluid temperatures or absorbed radiation. Our analysis demonstrates that TLB resolves thermal bottlenecks to restore Model Flops Utilization (MFU), while simultaneously reducing physical thermal stress. Extending the operational lifespan of orbital hardware is crucial to amortize the massive embodied carbon of rocket launches, outlining a necessary pathway to scale orbital AI without accelerating e-waste.

Original paperChinese poster

Compute–power coordination

05

GaN Power Devices and Converter Architectures for AI Data Centers: Efficiency, Reliability, and Deployment Pathways

arXivPreprint
Research overview

The growth of artificial-intelligence workloads is increasing the electrical and thermal demands on data-center power-delivery systems, making conversion efficiency, power density, and reliability critical design priorities. This review examines how gallium-nitride (GaN) power devices can be matched to specific stages of the grid-to-load conversion chain, including power-factor correction, isolated DC/DC conversion, 48-V intermediate-bus conversion, and point-of-load regulation. Si, SiC, and GaN are compared using converter-relevant metrics, and lateral, vertical, and specialized GaN architectures are evaluated in terms of voltage scalability, switching behavior, reverse conduction, thermal pathways, gate control, and technology maturity. The analysis shows that GaN provides a stage-dependent rather than universal advantage. Commercial lateral GaN HEMTs are particularly effective in high-frequency, low-to-mid-voltage stages, while specialized and hybrid devices support bidirectional operation, normally-off control, extreme conversion ratios, and integration. Vertical GaN remains an emerging option for higher-voltage and higher-power conversion. A quantitative framework links cascaded converter efficiency to electrical-loss reduction, cooling demand, annual facility energy use, and operational carbon emissions. Broad deployment further requires low-parasitic packaging, disciplined gate-drive and EMI co-design, mission-profile reliability qualification, scalable manufacturing, and supply-chain resilience. GaN is therefore best treated as a stage-specific system lever whose value depends on coordinated device, topology, package, and thermal co-design.

Abstract & detailed commentary

Donald Intal, Abasifreke Ebong

Chinese abstract

The growth of artificial-intelligence workloads is increasing the electrical and thermal demands on data-center power-delivery systems, making conversion efficiency, power density, and reliability critical design priorities. This review examines how gallium-nitride (GaN) power devices can be matched to specific stages of the grid-to-load conversion chain, including power-factor correction, isolated DC/DC conversion, 48-V intermediate-bus conversion, and point-of-load regulation. Si, SiC, and GaN are compared using converter-relevant metrics, and lateral, vertical, and specialized GaN architectures are evaluated in terms of voltage scalability, switching behavior, reverse conduction, thermal pathways, gate control, and technology maturity. The analysis shows that GaN provides a stage-dependent rather than universal advantage. Commercial lateral GaN HEMTs are particularly effective in high-frequency, low-to-mid-voltage stages, while specialized and hybrid devices support bidirectional operation, normally-off control, extreme conversion ratios, and integration. Vertical GaN remains an emerging option for higher-voltage and higher-power conversion. A quantitative framework links cascaded converter efficiency to electrical-loss reduction, cooling demand, annual facility energy use, and operational carbon emissions. Broad deployment further requires low-parasitic packaging, disciplined gate-drive and EMI co-design, mission-profile reliability qualification, scalable manufacturing, and supply-chain resilience. GaN is therefore best treated as a stage-specific system lever whose value depends on coordinated device, topology, package, and thermal co-design.

Original paperChinese poster

Compute–power coordination

06

Toward Next-Generation AI Data Centers: Power Delivery Architecture Shifts, Emerging Technologies, and Challenges

arXivPreprint
Research overview

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enabling technological building blocks: high-voltage conversion-ratio DC/DC converters, facility-level low-voltage DC distribution, and medium-voltage solid-state transformers. The advantages, technical challenges, and potential solutions associated with each building block are reviewed. Finally, future research directions and open challenges are discussed.

Abstract & detailed commentary

Sangwhee Lee, Rafal P. Wojda, Cheol-Hee Jo, Shuntaro Inoue, Pedro Ribeiro, Gui-Jia Su, Mostak Mohammad, Himel Barua

Chinese abstract

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enabling technological building blocks: high-voltage conversion-ratio DC/DC converters, facility-level low-voltage DC distribution, and medium-voltage solid-state transformers. The advantages, technical challenges, and potential solutions associated with each building block are reviewed. Finally, future research directions and open challenges are discussed.

Original paperChinese poster

AI & modeling

07

Pushing the Frontiers for Floating Solar Photovoltaics -- The Case for South America

arXivPreprint
Research overview

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Abstract & detailed commentary

Soham Ghosh, Anik Goswami, Krishna Kumba

Chinese abstract

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Original paperChinese poster

Compute–power coordination

08

Power-Flexible AI Data Centers: A New Paradigm for Grid-Responsive Compute

arXivPreprint
Research overview

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.

Abstract & detailed commentary

Chris Williams, Philip Colangelo, Ayse Coskun, Ethan Levine, Andy Neale, Ciaran Roberts, Shayan Sengupta, Nikhil Shirolkar

Chinese abstract

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.

Original paperChinese poster