Research connecting computing, power and thermal management

DAILY RESEARCH EDITIONCooling · Compute–power coordination · AI infrastructure

In focus/ Research highlights

8 papers3 research areas

Cooling & thermal management/ In focus

Revisiting "Cooler is Better": ITD-Aware Per-CPU Thermal Optimization for Sustainable Data Center Operation

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

arXivPreprint
Read the paper & insight

Compute–power coordination/ Related research

Spatial Load Correlation in AI Data-Center-Dominated Power Systems

The proliferation of large-scale data centers introduces spatially correlated demand profiles that challenge the long-standing assumption of statistical independence of loads in power system analysis. This paper examines the emergence of such load correlations and evaluates their impact on data-center-dominated grids. Analytical derivations reveal that correlated load fluctuations amplify aggregate stochastic disturbances, reduce voltage stability margins through weakened reactive power stiffness, and degrade frequency stability margin by erosion of natural load diversity effects. Real-time digital simulation studies confirm that moderate spatial correlation in distributed data centers produces simultaneous frequency deviations and voltage fluctuations across multiple buses. The findings offer transmission system operators a physics-based perspective to interpret emerging oscillatory phenomena and establish stability planning criteria grounded in measurable load-correlation structures rather than traditional diversity assumptions.

arXivPreprint

AI & modeling/ Related research

Data Center Life Cycle Co-Design Optimization

Liquid cooled supercomputers dissipate tens of megawatts of waste heat through cooling plants organized as parallel subloops that serve coolant distribution units. The number of subloops and the assignment of units to them are design decisions fixed at construction, yet they have not been systematically optimized for facilities at this scale. As electricity grids decarbonize, embodied carbon becomes a larger share of facility life cycle emissions and the cost of an unnecessary subloop becomes harder to justify. We present a framework that integrates operational energy from a validated control optimizer based on sequential least squares programming, embodied carbon from a bill of materials, and expected unplanned downtime from a per subloop reliability model. The framework is applied to the Frontier supercomputer, evaluating all 611 ways of partitioning its 25 coolant distribution units into two through six subloops. The life cycle cost and carbon optimum is found at two subloops holding 14 and 11 units, achieving 3,320.7 tonnes of carbon dioxide equivalent and $3.99 million over a seven year horizon, a saving of 50.2 tonnes and $100,000 compared to built four subloop configuration. The optimum remains on the Pareto front in all 15 scenarios of a one at a time sensitivity sweep. A semi-analytical decision rule generalizes the result, predicting four subloops for Aurora, two for El Capitan, and one for LUMI. When reliability is treated as a hard constraint set by operations policy, the four subloop Frontier deployment is consistent with the constrained optimum.

arXivPreprint

READING NOTEStart with the research insight, then examine the methods, comparisons and conditions.

RESEARCH & PERSPECTIVES

Papers & insights

Leave each paper with a question worth pursuing.

8 papers

Compute–power coordination

01

Spatial Load Correlation in AI Data-Center-Dominated Power Systems

arXivPreprint
Research overview

The proliferation of large-scale data centers introduces spatially correlated demand profiles that challenge the long-standing assumption of statistical independence of loads in power system analysis. This paper examines the emergence of such load correlations and evaluates their impact on data-center-dominated grids. Analytical derivations reveal that correlated load fluctuations amplify aggregate stochastic disturbances, reduce voltage stability margins through weakened reactive power stiffness, and degrade frequency stability margin by erosion of natural load diversity effects. Real-time digital simulation studies confirm that moderate spatial correlation in distributed data centers produces simultaneous frequency deviations and voltage fluctuations across multiple buses. The findings offer transmission system operators a physics-based perspective to interpret emerging oscillatory phenomena and establish stability planning criteria grounded in measurable load-correlation structures rather than traditional diversity assumptions.

Abstract & detailed commentary

Chandan Chaudhary, Alaaeldein Abdelkader, Yansong Pei, Mohammed Benidris, Joydeep Mitra

Chinese abstract

The proliferation of large-scale data centers introduces spatially correlated demand profiles that challenge the long-standing assumption of statistical independence of loads in power system analysis. This paper examines the emergence of such load correlations and evaluates their impact on data-center-dominated grids. Analytical derivations reveal that correlated load fluctuations amplify aggregate stochastic disturbances, reduce voltage stability margins through weakened reactive power stiffness, and degrade frequency stability margin by erosion of natural load diversity effects. Real-time digital simulation studies confirm that moderate spatial correlation in distributed data centers produces simultaneous frequency deviations and voltage fluctuations across multiple buses. The findings offer transmission system operators a physics-based perspective to interpret emerging oscillatory phenomena and establish stability planning criteria grounded in measurable load-correlation structures rather than traditional diversity assumptions.

Original paperChinese poster

Compute–power coordination

02

Toward Next-Generation AI Data Centers: Power Delivery Architecture Shifts, Emerging Technologies, and Challenges

arXivPreprint
Research overview

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enabling technological building blocks: high-voltage conversion-ratio DC/DC converters, facility-level low-voltage DC distribution, and medium-voltage solid-state transformers. The advantages, technical challenges, and potential solutions associated with each building block are reviewed. Finally, future research directions and open challenges are discussed.

Abstract & detailed commentary

Sangwhee Lee, Rafal P. Wojda, Cheol-Hee Jo, Shuntaro Inoue, Pedro Ribeiro, Gui-Jia Su, Mostak Mohammad, Himel Barua

Chinese abstract

The rapid growth of AI workloads is driving unprecedented increases in data center power demand, current transients, and thermal stress, exposing fundamental limitations in traditional 48 V rack architectures, low-voltage AC distribution, and line-frequency transformer interfaces. This paper reviews the three stages of architectural shifts required to support next-generation AI data centers and identifies three enabling technological building blocks: high-voltage conversion-ratio DC/DC converters, facility-level low-voltage DC distribution, and medium-voltage solid-state transformers. The advantages, technical challenges, and potential solutions associated with each building block are reviewed. Finally, future research directions and open challenges are discussed.

Original paperChinese poster

AI & modeling

03

Data Center Life Cycle Co-Design Optimization

arXivPreprint
Research overview

Liquid cooled supercomputers dissipate tens of megawatts of waste heat through cooling plants organized as parallel subloops that serve coolant distribution units. The number of subloops and the assignment of units to them are design decisions fixed at construction, yet they have not been systematically optimized for facilities at this scale. As electricity grids decarbonize, embodied carbon becomes a larger share of facility life cycle emissions and the cost of an unnecessary subloop becomes harder to justify. We present a framework that integrates operational energy from a validated control optimizer based on sequential least squares programming, embodied carbon from a bill of materials, and expected unplanned downtime from a per subloop reliability model. The framework is applied to the Frontier supercomputer, evaluating all 611 ways of partitioning its 25 coolant distribution units into two through six subloops. The life cycle cost and carbon optimum is found at two subloops holding 14 and 11 units, achieving 3,320.7 tonnes of carbon dioxide equivalent and $3.99 million over a seven year horizon, a saving of 50.2 tonnes and $100,000 compared to built four subloop configuration. The optimum remains on the Pareto front in all 15 scenarios of a one at a time sensitivity sweep. A semi-analytical decision rule generalizes the result, predicting four subloops for Aurora, two for El Capitan, and one for LUMI. When reliability is treated as a hard constraint set by operations policy, the four subloop Frontier deployment is consistent with the constrained optimum.

Abstract & detailed commentary

Shrenik Jadhav, Vidhyashree Nagaraju, Zheng Liu

Chinese abstract

Liquid cooled supercomputers dissipate tens of megawatts of waste heat through cooling plants organized as parallel subloops that serve coolant distribution units. The number of subloops and the assignment of units to them are design decisions fixed at construction, yet they have not been systematically optimized for facilities at this scale. As electricity grids decarbonize, embodied carbon becomes a larger share of facility life cycle emissions and the cost of an unnecessary subloop becomes harder to justify. We present a framework that integrates operational energy from a validated control optimizer based on sequential least squares programming, embodied carbon from a bill of materials, and expected unplanned downtime from a per subloop reliability model. The framework is applied to the Frontier supercomputer, evaluating all 611 ways of partitioning its 25 coolant distribution units into two through six subloops. The life cycle cost and carbon optimum is found at two subloops holding 14 and 11 units, achieving 3,320.7 tonnes of carbon dioxide equivalent and $3.99 million over a seven year horizon, a saving of 50.2 tonnes and $100,000 compared to built four subloop configuration. The optimum remains on the Pareto front in all 15 scenarios of a one at a time sensitivity sweep. A semi-analytical decision rule generalizes the result, predicting four subloops for Aurora, two for El Capitan, and one for LUMI. When reliability is treated as a hard constraint set by operations policy, the four subloop Frontier deployment is consistent with the constrained optimum.

Original paperChinese poster

AI & modeling

04

Learning Burst-Aware Early Warning Models for Capacity Stress under AI Workload Surges in Hyperscale Data Centers

arXivPreprint
Research overview

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mechanisms. In this paper, we propose a deployment-oriented, burst-aware early warning framework for proactive capacity stress prediction under AI workload surges. We formulate the problem as a high-recall forecasting task over multivariate telemetry windows, with the explicit goal of enabling operational intervention before system degradation occurs. The proposed framework integrates workload intensity, temporal variation, and system pressure signals, and employs a lightweight tree-based learning model to capture nonlinear interactions in highly imbalanced environments. To evaluate the system under realistic conditions, we introduce an AI workload surge injection methodology that simulates burst-driven demand patterns observed in large-scale AI systems. Our XGBoost-based model achieves an ROC AUC of 0.697 and an AP of 0.670, significantly outperforming baseline methods. Under deployment-oriented threshold selection, the framework achieves a Recall of 0.914, enabling the detection of the majority of stress-prone periods with acceptable false-alarm cost. Beyond predictive performance, we show how the proposed framework can be integrated into operational control loops to support proactive actions such as workload throttling and resource scaling. Our results highlight the practical value of high-recall, learning-based early warning systems in enabling resilient and adaptive data center operations in the era of AI-driven workloads.

Abstract & detailed commentary

Zihan Yu, Xianling Zeng, Zhiming Xue, Yalun Qi, Sichen Zhao

Chinese abstract

The rapid growth of large-scale AI workloads, particularly Large Language Model (LLM) training and inference, is fundamentally reshaping the operational dynamics of hyperscale data centers. Unlike traditional cloud workloads, AI-driven jobs exhibit bursty, high-intensity, and rapidly shifting resource demands, often leading to sudden capacity stress that cannot be effectively handled by reactive threshold-based mechanisms. In this paper, we propose a deployment-oriented, burst-aware early warning framework for proactive capacity stress prediction under AI workload surges. We formulate the problem as a high-recall forecasting task over multivariate telemetry windows, with the explicit goal of enabling operational intervention before system degradation occurs. The proposed framework integrates workload intensity, temporal variation, and system pressure signals, and employs a lightweight tree-based learning model to capture nonlinear interactions in highly imbalanced environments. To evaluate the system under realistic conditions, we introduce an AI workload surge injection methodology that simulates burst-driven demand patterns observed in large-scale AI systems. Our XGBoost-based model achieves an ROC AUC of 0.697 and an AP of 0.670, significantly outperforming baseline methods. Under deployment-oriented threshold selection, the framework achieves a Recall of 0.914, enabling the detection of the majority of stress-prone periods with acceptable false-alarm cost. Beyond predictive performance, we show how the proposed framework can be integrated into operational control loops to support proactive actions such as workload throttling and resource scaling. Our results highlight the practical value of high-recall, learning-based early warning systems in enabling resilient and adaptive data center operations in the era of AI-driven workloads.

Original paperChinese poster

Compute–power coordination

05

Modal Analysis of Spatial Load Correlation in AI Data Center-Dominated Power Systems

arXivPreprint
Research overview

Hyperscale AI data centers induce spatially and temporally correlated load fluctuations that violate classical independence assumptions and are not captured by time-averaged spectral methods. These correlations are episodic and non-stationary, so they demand analysis that resolves transient structure. This paper applies Dynamic Mode Decomposition (DMD) to the temporal evolution of pairwise inter-bus correlation coefficients and forms a low-dimensional state representation that enables modal analysis without a stationarity assumption. The recovered modes distinguish sustained coherence, decaying transients, and intensifying events, and their oscillation timescales map to underlying physical coupling mechanisms. The method is evaluated on an IEEE 39-bus Real-Time Digital Simulator (RTDS) testbed with three converter-interfaced AI data center loads driven by synthetic workload profiles. A global analysis attributes the dominant correlation energy to a slow thermal band, and a sliding-window analysis identifies brief intensification events in a small fraction of windows that align with stochastic workload coincidences. Cross-validation with RTDS voltage coherence confirms elevated coupling during these intervals. The proposed modal growth indicator provides an early-warning signal of correlation intensification, with a lead of of about 4~s before pairwise coherence reaches its peak.

Abstract & detailed commentary

Chandan Chaudhary, Michael Murillo, Mohammed Ben-Idris, Joydeep Mitra, Dilip Pandit, Atri Bera

Chinese abstract

Hyperscale AI data centers induce spatially and temporally correlated load fluctuations that violate classical independence assumptions and are not captured by time-averaged spectral methods. These correlations are episodic and non-stationary, so they demand analysis that resolves transient structure. This paper applies Dynamic Mode Decomposition (DMD) to the temporal evolution of pairwise inter-bus correlation coefficients and forms a low-dimensional state representation that enables modal analysis without a stationarity assumption. The recovered modes distinguish sustained coherence, decaying transients, and intensifying events, and their oscillation timescales map to underlying physical coupling mechanisms. The method is evaluated on an IEEE 39-bus Real-Time Digital Simulator (RTDS) testbed with three converter-interfaced AI data center loads driven by synthetic workload profiles. A global analysis attributes the dominant correlation energy to a slow thermal band, and a sliding-window analysis identifies brief intensification events in a small fraction of windows that align with stochastic workload coincidences. Cross-validation with RTDS voltage coherence confirms elevated coupling during these intervals. The proposed modal growth indicator provides an early-warning signal of correlation intensification, with a lead of of about 4~s before pairwise coherence reaches its peak.

Original paperChinese poster

Compute–power coordination

06

Power-Flexible AI Data Centers: A New Paradigm for Grid-Responsive Compute

arXivPreprint
Research overview

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.

Abstract & detailed commentary

Chris Williams, Philip Colangelo, Ayse Coskun, Ethan Levine, Andy Neale, Ciaran Roberts, Shayan Sengupta, Nikhil Shirolkar

Chinese abstract

The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.

Original paperChinese poster

AI & modeling

07

Pushing the Frontiers for Floating Solar Photovoltaics -- The Case for South America

arXivPreprint
Research overview

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Abstract & detailed commentary

Soham Ghosh, Anik Goswami, Krishna Kumba

Chinese abstract

Floating solar photovoltaic (FSPV) systems provide a land-efficient pathway to expand clean electricity access in energy-poor regions. South America has among the highest global FSPV potential (approx 38.26 TWh per million acres of water surface), yet deployment remains limited. This study presents a techno-socio-economic framework to assess FSPV for energy access, water security, and grid flexibility, with case studies in Nicaragua, Honduras, and Guyana. Estimated yields for 50 to 398 MW systems exceed 1,500 to 2,000 kWh per kW annually with capacity factors above 20 percent. At El Cajon, FSPV could significantly reduce emissions relative to fossil generation. Results show competitive costs with land-based PV when accounting for avoided land use, shared hydropower infrastructure, and water benefits. The framework also highlights co-location with hydropower and AI data centers, offering a scalable model for deployment in underserved regions.

Original paperChinese poster

Cooling & thermal management

08

Revisiting "Cooler is Better": ITD-Aware Per-CPU Thermal Optimization for Sustainable Data Center Operation

arXivPreprint
Research overview

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

Abstract & detailed commentary

Jason Crop, Hayden Moore, Sudeep Pasricha

Chinese abstract

As data center energy demand approaches grid-level constraints, optimizing conventional server infrastructure is essential for sustainable growth. The long-standing assumption that "cooler is better", i.e., lower CPU temperatures reduce power, does not fully hold for modern low-voltage CPUs, where inverse temperature dependence (ITD) drives higher supply voltages at lower temperatures. This creates a non-monotonic performance-per-watt curve where efficiency peaks at an intermediate thermal point. In this paper, for the first time, we empirically characterize ITD on production Intel Xeon CPUs and demonstrate that efficiency-optimal temperatures are CPU part-specific, and frequently higher than typical data center operating conditions. Measurements from commercial cloud data center platforms (Amazon, Equinix) reveal that approximately half of modern high-power CPUs operate about 10°C below their efficiency-optimal thermal point. By implementing ITD-aware thermal grouping of CPUs and inlet temperature adjustments, data center operators can optimize facility-level cooling and overall sustainability. Our case study shows that this approach can reduce total data center energy by 4-13% without sacrificing performance or reliability.

Original paperChinese poster