Research Article算电协同

A Predict-then-Schedule framework for Power Distribution Networks with AI Data Centers

Siqi Yan, Jiebao Zhang, Xi Yao, Juan Huang, Ye Shi

Published 2026-07-20 · arXiv · Credibility S

The surge of GPU-intensive workloads in artificial intelligence (AI) data centers drives massive energy demands, leading to soaring costs and significant stress on local power distribution networks. Coordinating delay-tolerant workload scheduling with power grid conditions via precise workload prediction can mitigate these issues. However, a critical gap remains in conventional approaches, i.e., minimizing predictio…

Abstract, interpretation and reference

Abstract

The surge of GPU-intensive workloads in artificial intelligence (AI) data centers drives massive energy demands, leading to soaring costs and significant stress on local power distribution networks. Coordinating delay-tolerant workload scheduling with power grid conditions via precise workload prediction can mitigate these issues. However, a critical gap remains in conventional approaches, i.e., minimizing prediction error does not necessarily lead to minimized downstream operational loss. Hence, this paper proposes an end-to-end Predict-Then-Schedule (PTS) framework that integrates upstream workload prediction with downstream scheduling optimization. By leveraging differentiable convex optimization, the PTS framework maps input features directly to optimal scheduling and enables gradient-based training. Furthermore, to respect the data center's capacity, a workload over-shifted loss combining electricity cost with a penalty for load-shedding is introduced to evaluate scheduling quality. Experiments demonstrate that the proposed framework significantly reduces operational cost and enhances system security compared to the conventional two-stage baseline.

Full text 中文海报
算电协同 论文图示
Research Article算电协同

A Phased Development Framework Enabling Islanded Operation of Sustainable AI Data Centers With Onsite Grid-Following and Grid-Forming Energy Architectures

Soham Ghosh, Nabil Mohammed, Mohammad Ashraf Hossain Sadi

Published 2026-07-19 · arXiv · Credibility S

As hyperscale and colocation AI data centers continue to expand, the electric grid is increasingly required to support large, concentrated loads, with individual facilities ranging from 500 MW to 2 GW. Current projections estimate that approximately 50 GW of AI data center capacity will require grid connectivity in the United States by 2030. While prior research has extensively examined the environmental and operati…

Abstract, interpretation and reference

Abstract

As hyperscale and colocation AI data centers continue to expand, the electric grid is increasingly required to support large, concentrated loads, with individual facilities ranging from 500 MW to 2 GW. Current projections estimate that approximately 50 GW of AI data center capacity will require grid connectivity in the United States by 2030. While prior research has extensively examined the environmental and operational impacts of AI data centers, as well as their potential role as grid-interactive assets, limited attention has been given to the challenges associated with their scalable deployment through engineering, procurement, and construction (EPC) processes. This manuscript addresses this gap by proposing a phased development framework for AI data center expansion. The approach is designed to enable developers to meet aggressive time-to-market objectives while navigating multi-year constraints associated with interconnection approvals and lead times associated with the procurement of component equipment. A modular construction architecture is presented, along with a detailed analysis of integrated energy systems and the role of hybrid on-site generation in supporting incremental capacity growth. Electromagnetic transient simulations (EMT) are used to evaluate system performance, demonstrating that a combination of on-site natural gas generation and grid-forming energy storage can reliably support data center operations during early and intermediate deployment phases. The study further examines the transition to full grid interconnection, including the capability of the data center to operate in islanded mode during grid disturbances. Finally, the manuscript compares grid-forming control strategies for system reconnection and restoration under varying conditions.

Full text 中文海报
算电协同 论文图示
Research Article热管理与液冷

Assessing Risks of Hydro-Generator Shaft Fatigue from Data Center Load Oscillations

Kaustav Chatterjee, Meghana Ramesh, Shuchismita Biswas, Brett A. Ross, Antos C. Varghese, Sameer Nekkalapu, Slaven Kincic

Published 2026-07-15 · arXiv · Credibility S

Large AI data center loads can introduce persistent sub-synchronous active-power oscillations that may impact nearby generators by exciting torsional modes and increasing shaft stress. This paper presents a model-based framework for evaluating hydro-generator shaft fatigue risk under oscillatory loading. An electromagnetic transient simulation model is developed using a two-mass turbine-generator shaft representatio…

Abstract, interpretation and reference

Abstract

Large AI data center loads can introduce persistent sub-synchronous active-power oscillations that may impact nearby generators by exciting torsional modes and increasing shaft stress. This paper presents a model-based framework for evaluating hydro-generator shaft fatigue risk under oscillatory loading. An electromagnetic transient simulation model is developed using a two-mass turbine-generator shaft representation with parameters from real-world generation units and a configurable AI data center load. The risk assessment is performed in two stages. First, a network transfer function quantifies the propagation of load oscillations from the data center point of interconnection to the hydro-generator terminal. A plant transfer function then characterizes the resulting shaft torque amplification. A frequency-scan approach identifies resonance regions and evaluates torque amplification at individual forcing frequencies. Parametric studies show that amplification is strongly affected by generator-to-turbine inertia ratio and torsional damping. Lower inertia ratios shift torsional modes to lower frequencies and increase amplification, indicating that some Kaplan-type units may be more susceptible than comparable Francis or Pelton units. Reduced damping further increases resonant response and fatigue exposure. A simplified fatigue assessment based on S--N curves and the Goodman diagram relates simulated torque response to mechanical integrity. The resulting Goodman safety factor provides a practical metric for evaluating the impact of persistent AI data center oscillations on hydro-generator service life and supports interconnection studies, oscillation limits, and plant-level monitoring strategies.

Full text 中文海报
热管理与液冷 论文图示
Research Article热管理与液冷

The Cost and Network Limits of Space-Based AI Compute

Kees van Berkel

Published 2026-07-15 · arXiv · Credibility S

This paper evaluates whether large-scale AI data centers deployed in low-Earth orbit (LEO) could become a cost-effective alternative to terrestrial facilities. The analysis compares orbital and ground-based systems across launch cost, power generation, cooling, radiation exposure, and atmospheric reentry, as well as compute-network performance. A key distinction is the shift from terrestrial Clos networks to space-b…

Abstract, interpretation and reference

Abstract

This paper evaluates whether large-scale AI data centers deployed in low-Earth orbit (LEO) could become a cost-effective alternative to terrestrial facilities. The analysis compares orbital and ground-based systems across launch cost, power generation, cooling, radiation exposure, and atmospheric reentry, as well as compute-network performance. A key distinction is the shift from terrestrial Clos networks to space-based mesh networks using laser inter-satellite links. Using bisection bandwidth, bisection intensity, and roofline-style models, we show that while LEO-based inference may be feasible, training frontier-scale LLMs in orbit is unlikely to be competitive with terrestrial data centers.

Full text 中文海报
热管理与液冷 论文图示
Research Article算电协同

A Hierarchical Semi-Markov Load Model for AI Data Centers Coupling Job Scheduling with Bulk-Synchronous-Parallel Power Dynamics

Chandan Chaudhary, Atri Bera, Cody Newlun, Mohammed Ben-Idris, Joydeep Mitra

Published 2026-07-13 · arXiv · Credibility S

AI data centers are emerging as a dominant new load class with their power dynamics fundamentally from conventional industrial loads. Inside a training job, the bulk-synchronous-parallel algorithm moves each node through compute, sync, and checkpoint steps, which swings power between full load and near idle within seconds. Across the whole facility, jobs arrive, take blocks of nodes for hours to days, then leave, so…

Abstract, interpretation and reference

Abstract

AI data centers are emerging as a dominant new load class with their power dynamics fundamentally from conventional industrial loads. Inside a training job, the bulk-synchronous-parallel algorithm moves each node through compute, sync, and checkpoint steps, which swings power between full load and near idle within seconds. Across the whole facility, jobs arrive, take blocks of nodes for hours to days, then leave, so the number of busy nodes changes daily, weekly, and yearly. This slower shift drives facility-wide swings and the peak demand that sets the size of the grid link. A model that looks only at within-job behavior, and treats the facility as a fixed set of busy nodes, smooths out these swings and misses the true peak-to-average ratio. This paper develops a hierarchical semi-Markov Data-Center (HSM-DC) load model that couples two layers across two timescales. A job-scheduling layer creates jobs through a non-homogeneous compound-Poisson process shaped by daily, weekly, and seasonal patterns, gives each job a heavy-tailed node count and length, and places jobs on a fixed pool of nodes on a first-come basis. A within-job layer moves each busy node through a five-state semi-Markov chain for the BSP steps, with state-based Ornstein-Uhlenbeck noise. Facility power comes from this changing node count and the per-node power, set to match measured node data and the facility's straight-line power-versus-load curve. Configured to the reference facility at the same scale, the model matches mean power, its spread, and the peak-to-average ratio across load levels, with fit scores of 0.9997, 0.92, and 0.82. It also matches the share of queued jobs to within one point at high load. Facility-wide swings and peak demand come from how jobs arrive and get scheduled, so grid planning must model that process, not just scale up a single node's power curve.

Full text 中文海报
算电协同 论文图示
Research Article算电协同

The Environmental Cost of Digital Sovereignty: Water, Energy, and Emissions Impacts of Sovereign AI Infrastructure in the Global South

Muntaser Syed, Marius C. Silaghi, Sheikh Abujar, Sharun Akter Khushbu, Amal El Ahmad

Published 2026-07-15 · arXiv · Credibility S

Sovereign AI has become a strategic priority across the Global South, with over \$200 billion in state-led commitments announced between 2024 and 2026. Yet the physical infrastructure that compute sovereignty demands, above all data centers, imposes water, energy, and carbon costs that fall hardest on countries least equipped to absorb them. This paper presents a comparative environmental stress analysis across four…

Abstract, interpretation and reference

Abstract

Sovereign AI has become a strategic priority across the Global South, with over \$200 billion in state-led commitments announced between 2024 and 2026. Yet the physical infrastructure that compute sovereignty demands, above all data centers, imposes water, energy, and carbon costs that fall hardest on countries least equipped to absorb them. This paper presents a comparative environmental stress analysis across four cases: the United Arab Emirates, Bangladesh, India, and Africa (with a focus on Kenya). Using publicly available water stress data, grid carbon intensity factors, and GPU power specifications, we model the water consumption, energy demand, and carbon emissions of hypothetical sovereign AI deployments under multiple cooling technology scenarios. We find that a 1,024-GPU cluster using evaporative cooling in the UAE would consume over 30 million liters of water annually in a country classified as ``extremely high'' water stress. In Bangladesh, sovereign AI policy documents call for centralized GPU procurement but do not address where to site data centers in a country where more than a fifth of the land floods in an average year and the power grid struggles to deliver reliable supply. We identify a sovereignty-sustainability trilemma in which no country can simultaneously maximize AI sovereignty, minimize environmental impact, and maintain affordable resource access for citizens. We propose design principles for environmentally responsible sovereign AI, including mandatory water usage effectiveness reporting, climate-vulnerability siting assessments, and a preference for frugal small language models over frontier pre-training in resource-constrained settings.

Full text 中文海报
算电协同 论文图示
Research Article热管理与液冷

Classical Reversible Computation by Quantum Coherence

Daniel Loss

Published 2026-07-07 · arXiv · Credibility S

Rising energy demand from data-center and AI applications has renewed interest in reversible computation, where logic need not dissipate heat at every step if information is uncomputed. Implementations have so far been classical: adiabatic CMOS reduces dissipation by slowing charge motion but is still limited by the threshold physics of transistors. Here we propose classical reversible logic implemented by coherent …

Abstract, interpretation and reference

Abstract

Rising energy demand from data-center and AI applications has renewed interest in reversible computation, where logic need not dissipate heat at every step if information is uncomputed. Implementations have so far been classical: adiabatic CMOS reduces dissipation by slowing charge motion but is still limited by the threshold physics of transistors. Here we propose classical reversible logic implemented by coherent spin dynamics in a spin quantum-dot array, with inputs and outputs in classical basis states and no algorithmic use of superposition. The same spin stores, transports, and computes, with unitary rotation replacing irreversible switching. The universal building block is an iToffoli gate driven by DC voltage pulses and anisotropic exchange in Ge/Si hole spins. Simulations with experimental parameters reproduce the Toffoli truth table and yield a testable error landscape. Because shuttling transports the bit without measurement, logic and data movement remain reversible until readout. Millivolt pulses on femtofarad gates yield a gate energy below the 4 K Landauer scale, about five (eight) orders of magnitude below a room-temperature CMOS Toffoli with (without) 4 K cooling overhead. The same semiconductor hardware is therefore dual-use, supporting quantum algorithms when superposition is used and classical reversible logic otherwise.

Full text 中文海报
热管理与液冷 论文图示
Research Article算电协同

Large-Load Demand Flexibility as Virtual Storage

Chandan Chaudhary, Mohammed Ben-Idris, Joydeep Mitra

Published 2026-07-06 · arXiv · Credibility S

Water electrolysis plants, hyperscale data centers, and aluminum potlines represent gigawatts of demand-side flexibility for bulk power system balancing, operational planning, and procurement services. Such loads are scheduled through per-interval power bounds and horizon energy windows, whereas co-located battery energy storage systems (BESS) operate under state-of-charge dynamics. The two formulations share no com…

Abstract, interpretation and reference

Abstract

Water electrolysis plants, hyperscale data centers, and aluminum potlines represent gigawatts of demand-side flexibility for bulk power system balancing, operational planning, and procurement services. Such loads are scheduled through per-interval power bounds and horizon energy windows, whereas co-located battery energy storage systems (BESS) operate under state-of-charge dynamics. The two formulations share no common mathematical structure, and the joint procurement value of co-located loads and storage goes unrealized as a result. This paper establishes the connection between the two formulations through a virtual storage (VS) equivalence. Every feasible large-load trajectory under power-bound and energy-window constraints is a valid charge trajectory of a VS device that operates at unity accounting efficiency in the grid power balance. Production and service-level costs lie outside this abstraction and enter the dispatch through curtailment opportunity costs. For a portfolio co-located with a BESS, aggregation reduces the constraint count from O(NT) to O(T) and yields a co-dispatch price for both resources. Validation on the IEEE RTS-GMLC with three representative load classes shows that virtual storage delivers the dominant share of joint procurement savings. In the tested case, savings are additive because the two resources dispatch to non-overlapping intervals, and the curtailment shadow price tracks the peak-price band onset rather than the daily peak price.

Full text 中文海报