Liquid Cooling AI Data Center Power & Thermal Systems
Current Issue

Volume 2026 · Issue 08-13

按期刊卷期页方式整理本期论文。每条仅使用日报已列出的可追溯公开来源,不新增未经核验事实。

Research Article算电协同

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun

Published 2026-08-11 · arXiv · Credibility S

The rapid growth of large language model (LLM) services is accelerating the expansion of AI data centers (AIDCs), intensifying concerns over power system resource adequacy and rising carbon emissions. The integration of renewable energy provides a pathway toward addressing these pressures, but it also introduces new cross-domain stability challenges to low-carbon AIDCs. For example, variability in renewable generati…

Abstract, interpretation and reference

Abstract

The rapid growth of large language model (LLM) services is accelerating the expansion of AI data centers (AIDCs), intensifying concerns over power system resource adequacy and rising carbon emissions. The integration of renewable energy provides a pathway toward addressing these pressures, but it also introduces new cross-domain stability challenges to low-carbon AIDCs. For example, variability in renewable generation affects reliability on the supply side, whereas fluctuations in AIDC workloads affect reliability on the demand side, jointly creating interconnected stability risks in AIDC microgrids. To address this problem, this paper is the first to explore computing-power coordinated attacks against low-carbon AIDCs. First, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework to capture two interacting attack surfaces: inverter control parameter tampering attacks, and AI-induced demand manipulation attacks. Then, accounting for renewable-side forecast uncertainty and AIDC-side demand response uncertainty, we introduce confidence-weighted realizations and construct a long-term attack reachable domain analysis. Furthermore, an impedance-based screening method is utilised to map generation and load variations to erosion of stability margin, thereby identifying vulnerable attack time windows and attack vectors. In addition, case studies show that computing-power coordinated attacks induce sustained inverter frequency excursions exceeding 20% of the nominal value and reach instability conditions unattainable by single attacks. The results also demonstrate that the proposed framework can extract sparse, high-confidence vulnerable periods from long-term operating trajectories.

Full text 中文海报
算电协同 论文图示
Research Article芯片与算力

Towards Terabit/$λ$/s Multidimensional Silicon Photonic Engine

Hao Chen, Zengqi Chen, Wu Zhou, Kaihang Lu, Mingyuan Zhang, Yuxiang Yin, Yiou Cui, Chaoran Huang, Pui-In Mak, Yeyu Tong

Published 2026-08-12 · arXiv · Credibility S

Increasing artificial intelligence (AI) workloads drive co-packaged optics (CPO), which integrates optical engines with electronic components. Optical interconnects can extend transmission distances and reduce latency, allowing distributed clusters in AI factories to operate as a unified computational unit. However, escalating data throughput necessitates greater parallelization of light within ultracompact form fac…

Abstract, interpretation and reference

Abstract

Increasing artificial intelligence (AI) workloads drive co-packaged optics (CPO), which integrates optical engines with electronic components. Optical interconnects can extend transmission distances and reduce latency, allowing distributed clusters in AI factories to operate as a unified computational unit. However, escalating data throughput necessitates greater parallelization of light within ultracompact form factors while maintaining stringent energy efficiency and latency constraints. Here, we present a multidimensional silicon photonic engine that achieves a communication capacity exceeding 1.8 terabit/s/lambda/s. By monolithically integrating transceivers, spatial and polarization (de)multiplexers, and optical signal processors on a single chip, we eliminate bulky discrete (de)multiplexers and power-hungry digital signal processing (DSP). In experiments, the photonic engine can be self-configured to identify two, four, or six concurrent spatial and polarization channels per fiber while mitigating dynamic channel crosstalk. Compared with the state-of-art DSP, our approach achieves >5,000-fold reductions in both power consumption and processing latency at a MIMO processing order of six. Furthermore, we demonstrate full-duplex, modulation-format-transparent inter-chip communication over 300-meter fiber. These results represent a paradigm shift for optical engines in future high-performance computing and AI-driven data centers.

Full text 中文海报
芯片与算力 论文图示
Research Article算电协同

Environmental and Economic Implications of Artificial Intelligence Data Centers in the United States

Johanna Bolaños-Zuñiga, Alberto J. Lamadrid

Published 2026-08-10 · arXiv · Credibility S

In this study, we use electricity demand growth, cooling requirements, and backup system operation to evaluate the environmental and economic implications of artificial intelligence data centers in the United States. Our results indicate that impacts are not determined solely by facility design, but by the broader electricity, water, and land-use systems in which these facilities operate. Emissions are primarily dri…

Abstract, interpretation and reference

Abstract

In this study, we use electricity demand growth, cooling requirements, and backup system operation to evaluate the environmental and economic implications of artificial intelligence data centers in the United States. Our results indicate that impacts are not determined solely by facility design, but by the broader electricity, water, and land-use systems in which these facilities operate. Emissions are primarily driven by electricity consumption and therefore depend on marginal generation mixes, transmission constraints, and the spatial and temporal distribution of demand. Analysis further shows that local effects include pressures on water resources, increased noise exposure, and land-use changes, with outcomes varying across regions and infrastructure conditions. The assessment of technological and operational measures shows that improvements in energy efficiency, cooling configurations, and operational strategies can reduce these impacts, although their effectiveness depends on system-level conditions. Evaluation of regulatory and market structures suggests that existing frameworks may not fully account for location- and time-specific externalities. These findings support the need for integrated policy approaches that align data center deployment and operation with electricity system characteristics, water availability, and land-use planning to improve overall environmental and economic performance.

Full text 中文海报
算电协同 论文图示
Research Article算电协同

Beyond the Grid: Cost, Carbon, and Capital Requirements of On-Site Power Technologies for AI Data Centers

Eliseo Curcio

Published 2026-08-08 · arXiv · Credibility S

Interconnection queues, not electricity prices, now govern where data centers can be built, and the standard levelized-cost comparison answers a question no developer faces: it assumes a load profile, freezes the grid price while modeling the demand that moves it, and quotes busbar costs a facility cannot buy. This paper evaluates nine on-site supply technologies against a delivered grid whose price is endogenous to…

Abstract, interpretation and reference

Abstract

Interconnection queues, not electricity prices, now govern where data centers can be built, and the standard levelized-cost comparison answers a question no developer faces: it assumes a load profile, freezes the grid price while modeling the demand that moves it, and quotes busbar costs a facility cannot buy. This paper evaluates nine on-site supply technologies against a delivered grid whose price is endogenous to projected data-center demand, on a complete-site basis that retains standby charges, with measured GPU training load, delivered fuel prices, production-pathway carbon, and statutory 45V and 48E incentive mechanics. Nothing beats the wire: gas combined cycle produces at 47 USD/MWh but costs about 114 USD per megawatt-hour of complete site energy against a 92 USD grid; four-hour storage is physically capped near 18 percent of annual energy and, charged at the margin, dirtier than the grid; hydrogen from grid-priced power fails on cost and carbon together. An investment inversion converts these findings into capital terms: conversion-hardware learning buys nothing, because free hardware still exceeds the grid for every low-carbon arm, while global electrolyser deployment on sited sub-20 USD/MWh power brings PEM hydrogen power to about 2.2 times the grid at 300 billion USD and 1.9 times at 1 trillion USD (2.7 and 2.3 for the hydrogen engine), with a carbon reduction of roughly 85 percent (6.8-fold) against grid-power production. Grid parity is not purchasable at any budget. On-site supply is an access and depth product; most current investment targets the wrong term.

Full text 中文海报
算电协同 论文图示
Research Article芯片与算力

ClusterBench: A Framework for Cluster-Wide Continuous Benchmarking and Regression Testing

Aditya Ujeniya, Jan Eitzinger, Thomas Gruber, Georg Hager, Gerhard Wellein

Published 2026-08-11 · arXiv · Credibility S

Data centers need tooling that validates an entire installation rather than individual nodes, at acceptance and at regular intervals thereafter. This requires dispatching identical benchmarks to every node in a single submission, and therefore cluster-aware scheduling. This paper presents ClusterBench, a framework for cluster-wide continuous benchmarking. It ships with a benchmark collection targeting each component…

Abstract, interpretation and reference

Abstract

Data centers need tooling that validates an entire installation rather than individual nodes, at acceptance and at regular intervals thereafter. This requires dispatching identical benchmarks to every node in a single submission, and therefore cluster-aware scheduling. This paper presents ClusterBench, a framework for cluster-wide continuous benchmarking. It ships with a benchmark collection targeting each component: CPU, GPU, memory, interconnect, and I/O. Because measurements are repeated throughout the cluster's lifetime, ClusterBench collects data across space and time. Comparison against earlier runs detects performance regressions introduced by software changes, such as kernel updates or new library versions. The measurements also form a dataset for research on hardware variability. On the NHR@FAU clusters Helma, Alex, and Fritz, variation within a single component stays within 1%. Variation across specimens reaches 5%, despite nodes identical by specification. Correlating performance with power draw, frequency, and temperature shows that this relationship differs between air- and liquid-cooled nodes.

Full text 中文海报
芯片与算力 论文图示
Research Article算电协同

Techno-Economic Boundary Analysis of Small Modular Reactor Cogeneration for Hyperscale Data Center IT and Cooling Loads

Honglin Li, Buxin She, Jie Zhang

Published 2026-08-11 · arXiv · Credibility S

Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions t…

Abstract, interpretation and reference

Abstract

Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions that must coincide. Here we co-optimize reactor dispatch, steam extraction, absorption cooling and grid exchange hourly for a 200 MW$_\mathrm{e}$ data center in the Electric Reliability Council of Texas (ERCOT) region, across 109 runs spanning capital, market, policy, financing and cooling efficiency. At 2023 mid-range reactor capital, the nuclear configurations cost 49-62% more than grid supply even with the Section 45Y production tax credit. The viable region opens near \$5,000 kW$_\mathrm{e}^{-1}$, and nth-of-a-kind capital makes them 77-89% cheaper in 2023, though between parity and 34% more expensive in the low-price 2024 market. A carbon price of \$53-64 tCO$_2^{-1}$ closes the mid-range gap under hourly export crediting. Absorption cooling is dispatched in response to hourly electricity prices and supplies 38% of annual cooling, at an added cost of \$9.2 million yr$^{-1}$ relative to the reactor-only plant; that gap closes at an installed absorption cost of \$60 kW$_\mathrm{c}^{-1}$ at baseline efficiency and \$570 kW$_\mathrm{c}^{-1}$ on a legacy-efficiency campus, against surveyed commercial prices of \$450-1,200 kW$_\mathrm{c}^{-1}$. Together these results delineate the capital, market and policy conditions under which colocated reactor cogeneration is competitive with grid procurement, and the range over which each condition moves the outcome.

Full text 中文海报
算电协同 论文图示