Research Article热管理与液冷
Can Emre Koksal、Richard A. Barry、Artun Sel
Published 2026-08-13 · arXiv · Credibility S
The growing power demands and variability of AI
Abstract, interpretation and reference
Abstract
The growing power demands and variability of AI
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用文献摘要中的模型、实验或案例分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向冷却效率、能源利用或运维策略的改进方向。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Can Emre Koksal, Richard A. Barry, Artun Sel. A Theory of Probabilistic Power Provisioning for Data Centers with Distributed Energy Storage[J/OL]. (2026-08-13)[2026-08-15]. https://arxiv.org/abs/2608.12993.
Research Article算电协同
Honglin Li、Buxin She、Jie Zhang
Published 2026-08-11 · arXiv · Credibility S
Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions t…
Abstract, interpretation and reference
Abstract
Hyperscale data centers are adding firm, high-utilization demand faster than grids can serve it, renewing interest in colocating them with small modular reactors. Such a plant could earn revenue in two ways, selling low-carbon power and diverting steam to absorption chillers that serve a cooling load accounting for 20-40% of facility electricity use, but neither revenue stream has been priced across the conditions that must coincide. Here we co-optimize reactor dispatch, steam extraction, absorption cooling and grid exchange hourly for a 200 MW$_\mathrm{e}$ data center in the Electric Reliability Council of Texas (ERCOT) region, across 109 runs spanning capital, market, policy, financing and cooling efficiency. At 2023 mid-range reactor capital, the nuclear configurations cost 49-62% more than grid supply even with the Section 45Y production tax credit. The viable region opens near \$5,000 kW$_\mathrm{e}^{-1}$, and nth-of-a-kind capital makes them 77-89% cheaper in 2023, though between parity and 34% more expensive in the low-price 2024 market. A carbon price of \$53-64 tCO$_2^{-1}$ closes the mid-range gap under hourly export crediting. Absorption cooling is dispatched in response to hourly electricity prices and supplies 38% of annual cooling, at an added cost of \$9.2 million yr$^{-1}$ relative to the reactor-only plant; that gap closes at an installed absorption cost of \$60 kW$_\mathrm{c}^{-1}$ at baseline efficiency and \$570 kW$_\mathrm{c}^{-1}$ on a legacy-efficiency campus, against surveyed commercial prices of \$450-1,200 kW$_\mathrm{c}^{-1}$. Together these results delineate the capital, market and policy conditions under which colocated reactor cogeneration is competitive with grid procurement, and the range over which each condition moves the outcome.
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用综述归纳和指标比较,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Honglin Li, Buxin She, Jie Zhang. Techno-Economic Boundary Analysis of Small Modular Reactor Cogeneration for Hyperscale Data Center IT and Cooling Loads[J/OL]. (2026-08-11)[2026-08-15]. http://arxiv.org/abs/2608.10999v1.
Research ArticleAI 运维优化
Yifu Ding、Zixi Chen、Ruicheng Ao、David Simchi-Levi、Thomas Magnanti
Published 2026-08-01 · arXiv · Credibility S
The rapid rise in energy
Abstract, interpretation and reference
Abstract
The rapid rise in energy
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,AI 运维、负载预测和设施调优正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向跨地域数据中心负载与电力资源之间的调度关系。意义:对日报读者而言,它可用于判断AI 工具是否能降低运维复杂度并提升可用性。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Yifu Ding, Zixi Chen, Ruicheng Ao, 等. Refined Thompson Learning for Adaptive Bandits: Sustainable Power-Efficient Flexibility Scheduling Across Data Centers[J/OL]. (2026-08-01)[2026-08-15]. https://arxiv.org/abs/2608.00921.
Research Article热管理与液冷
Nicoletta Tsiopani、Moysis Symeonides、George Pallis、Marios D. Dikaiakos
Published 2026-08-13 · arXiv · Credibility S
The rapid growth of LLM inference is shifting sustainability concerns from one-time training to continuous serving, where infrastructure decisions shape energy
Abstract, interpretation and reference
Abstract
The rapid growth of LLM inference is shifting sustainability concerns from one-time training to continuous serving, where infrastructure decisions shape energy
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用文献摘要中的模型、实验或案例分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向跨地域数据中心负载与电力资源之间的调度关系。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Nicoletta Tsiopani, Moysis Symeonides, George Pallis, 等. InFactPlanner: Planning Sustainable Geo-Distributed LLM Data Centers[J/OL]. (2026-08-13)[2026-08-15]. https://arxiv.org/abs/2608.12915.
Research Article算电协同
Ze Yu、Hongwei Zhen、Chao Shen、Mingyang Sun
Published 2026-08-11 · arXiv · Credibility S
The rapid growth of large language model (LLM) services is accelerating the expansion of AI
Abstract, interpretation and reference
Abstract
The rapid growth of large language model (LLM) services is accelerating the expansion of AI
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,算力负载与电网侧资源的协同调度正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用仿真建模和情景分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向AI 负载波动对电网设备寿命和调频边界的影响。意义:对日报读者而言,它可用于判断智算中心建设是否受电网容量、负载波动和调度机制约束。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Ze Yu, Hongwei Zhen, Chao Shen, 等. AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks[J/OL]. (2026-08-11)[2026-08-15]. https://arxiv.org/abs/2608.10645.
Research Article热管理与液冷
Hao Chen、Zengqi Chen、Wu Zhou、Kaihang Lu、Mingyuan Zhang、Yuxiang Yin、Yiou Cui、Chaoran Huang
Published 2026-08-12 · arXiv · Credibility S
Increasing artificial intelligence ( AI
Abstract, interpretation and reference
Abstract
Increasing artificial intelligence ( AI
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用文献摘要中的模型、实验或案例分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向冷却效率、能源利用或运维策略的改进方向。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Hao Chen, Zengqi Chen, Wu Zhou, 等. Towards Terabit/$λ$/s Multidimensional Silicon Photonic Engine[J/OL]. (2026-08-12)[2026-08-15]. https://arxiv.org/abs/2608.11639.
Research Article热管理与液冷
Aditya Ujeniya、Jan Eitzinger、Thomas Gruber、Georg Hager、Gerhard Wellein
Published 2026-08-11 · arXiv · Credibility S
Data
Abstract, interpretation and reference
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用框架构建和频域/系统级分析,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向冷却效率、能源利用或运维策略的改进方向。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Aditya Ujeniya, Jan Eitzinger, Thomas Gruber, 等. ClusterBench: A Framework for Cluster-Wide Continuous Benchmarking and Regression Testing[J/OL]. (2026-08-11)[2026-08-15]. https://arxiv.org/abs/2608.10956.
Research Article热管理与液冷
Shrenik Jadhav、Zheng Liu
Published 2026-08-07 · arXiv · Credibility S
Data
Abstract, interpretation and reference
中文解读
背景:AI 数据中心负载、功率密度和能源约束同步上升,液冷、热管理和数据中心能效正在成为智算中心设计的关键变量。问题:论文聚焦现有方案在效率、可靠性或工程协同上的瓶颈。方法:摘要显示作者采用建模优化、调度分析或算法评估,把运行负载、冷却/能源系统和基础设施约束放在同一分析框架中。结果:研究重点指向冷却效率、能源利用或运维策略的改进方向。意义:对日报读者而言,它可用于判断液冷方案、热管理路线和高密度部署节奏。仍需结合全文实验条件、样本范围和成本假设核验。
参考文献
Shrenik Jadhav, Zheng Liu. Digital Twin-Based Cooling System Optimization for Data Center[J/OL]. (2026-08-07)[2026-08-15]. https://arxiv.org/abs/2603.01198.