bupt.ai Research & perspectives

AIDC RESEARCH

Computing Research Frontiers.

Research connecting computing, power and thermal management

DAILY RESEARCH EDITIONCooling · Compute–power coordination · AI infrastructure

In focus/ Research highlights

8 papers3 research areas

Computing & systems/ In focus

Capturing Electrical Windows Through Reconfigurable Optical Networks: Transfer-aware Scheduling of Multi-Region AI Data Centers

Artificial-intelligence data centers (AIDCs) can provide spatiotemporal load flexibility by migrating training workloads in response to regional electricity prices and renewable-energy (RE) availability. However, transfer-blind scheduling may overestimate migration benefits by overlooking transfer time or prevent training from resuming within renewable-rich or low-price windows when considering transfer time. This paper proposes a transfer-aware compute-electricity-network scheduling framework that coordinates training placement, checkpoint transmission, and optical circuit switching (OCS) to improve local RE utilization and reduce grid-purchase cost. A compact compute-electricity master problem generates candidate schedules using estimated transfer delays. The framework then schedules optical circuits, verifies checkpoint delivery under shared-link capacity constraints, and revises infeasible schedules using updated delay estimates. It integrates day-ahead planning, event-triggered intraday updates, and real-time dispatch. In a five-AIDC benchmark with equal completed work and network resources, the proposed method reduces the real-time grid purchase cost by 12.50% and increases the local RE utilization by 2.724 percentage points relative to static optical operation. Sensitivity and ablation analyses indicate that OCS is particularly beneficial when renewable-rich or low-price windows shift across sites and network bottlenecks hinder timely checkpoint delivery.

arXivPreprint
Read the paper & insight

Computing & systems/ Related research

FALCON: FPGA-Accelerated Latency-Certifiable Occupancy Networks for Camera-Based Autonomous Driving

A perception system that must brake for a pedestrian does not need a low average latency. It must deliver an answer before the deadline on every frame, the worst case included. Commodity edge accelerators optimize the mean through dynamic scheduling, OS jitter, thermal throttling, and contention, so their per-frame latency can be measured but not bounded. We build FALCON, a camera-based 3D occupancy front-end on the AMD Kria KR260, an embedded FPGA drawing 4.3 W idle and up to 6.6 W under inference, and make the latency guarantee layered and explicit: programmable-logic (PL) compute is cycle-bounded analytically; inference is a measured envelope over 100k-frame traces; and a watchdog enforces output delivery, publishing the previous output flagged stale when a frame is late. The deadline runs use a fixed-work proxy of six ResNet-50 DPU inferences per frame, not the full occupancy network: across three 100k-frame enforced runs, all 300k proxy frames delivered an output within the 100 ms deadline plus at most 10.2 ms, the worst of the three runs. The full six-camera FlashOcc pipeline composes to about 1.3 s per frame on the board and is not yet a 10 Hz system. The two operations the DPU cannot run, a view-transform gather and a bilinear resize, become fixed-trip-count PL IPs numerically matched to their software references. On the full Occ3D-nuScenes validation set the board reaches mIoU 29.88, 92.8% of an FP32 baseline the DPU cannot run. On a ResNet-50 probe over 100k frames the KR260 tail stays within 1.5 times its median (2.0 times for the six-inference proxy), where Jetson Orin reaches 4.4 times and the worst datacenter GPU run (NVIDIA L4) 23.6 times. The deployment recipe, HLS sources, and raw timing traces are released.

arXivPreprint

Resources & environment/ Related research

Aging-Aware Online Distributed Scheduling for Lifecycle Carbon Reduction in Geo-Distributed Data Centers

The rapid proliferation of data centers (DCs), driven by cloud computing and artificial intelligence (AI), has led to massive energy demand and carbon emissions, posing significant sustainability challenges. Carbon-aware optimization in geographically distributed data centers has been widely studied. Most existing approaches mainly focus on operational carbon emissions from server usage. However, existing literature often ignores workload-induced thermal stress, which accelerates nonlinear hardware degradation. This leads to more frequent server replacements and ultimately increases embodied carbon emissions. To address these limitations, we propose a comprehensive carbon life-cycle modeling framework for distributed data centers. Apart from operational carbon emissions, this work combines workload scheduling with a utilization-dependent exponential aging model to evaluate long-term carbon costs from server degradation. In order to solve the proposed optimization model in an online and privacy-preserving manner, an enhanced Lyapunov framework with time-varying queue shifting (TVQS) is first introduced to handle system uncertainties. Then, a zero-sum perturbation-based alternating direction method of multipliers (ZSP-ADMM) framework is developed to enable distributed coordination across geographically separated data centers while protecting locally exchanged workload information. Simulation results demonstrate that the proposed approach achieves up to 13.0% lower carbon emissions and 12.6% lower operational costs compared with benchmarks.

arXivPreprint

READING NOTEStart with the research insight, then examine the methods, comparisons and conditions.

RESEARCH & PERSPECTIVES

Papers & insights

Leave each paper with a question worth pursuing.

8 papers

Computing & systems

01

Capturing Electrical Windows Through Reconfigurable Optical Networks: Transfer-aware Scheduling of Multi-Region AI Data Centers

arXivPreprint
Research overview

Artificial-intelligence data centers (AIDCs) can provide spatiotemporal load flexibility by migrating training workloads in response to regional electricity prices and renewable-energy (RE) availability. However, transfer-blind scheduling may overestimate migration benefits by overlooking transfer time or prevent training from resuming within renewable-rich or low-price windows when considering transfer time. This paper proposes a transfer-aware compute-electricity-network scheduling framework that coordinates training placement, checkpoint transmission, and optical circuit switching (OCS) to improve local RE utilization and reduce grid-purchase cost. A compact compute-electricity master problem generates candidate schedules using estimated transfer delays. The framework then schedules optical circuits, verifies checkpoint delivery under shared-link capacity constraints, and revises infeasible schedules using updated delay estimates. It integrates day-ahead planning, event-triggered intraday updates, and real-time dispatch. In a five-AIDC benchmark with equal completed work and network resources, the proposed method reduces the real-time grid purchase cost by 12.50% and increases the local RE utilization by 2.724 percentage points relative to static optical operation. Sensitivity and ablation analyses indicate that OCS is particularly beneficial when renewable-rich or low-price windows shift across sites and network bottlenecks hinder timely checkpoint delivery.

Abstract & detailed commentary

Xi Tong, Zijian Li, Xiaoyi Fan, Cong Zhang, Ershun Du, Qin Wang

Chinese abstract

Artificial-intelligence data centers (AIDCs) can provide spatiotemporal load flexibility by migrating training workloads in response to regional electricity prices and renewable-energy (RE) availability. However, transfer-blind scheduling may overestimate migration benefits by overlooking transfer time or prevent training from resuming within renewable-rich or low-price windows when considering transfer time. This paper proposes a transfer-aware compute-electricity-network scheduling framework that coordinates training placement, checkpoint transmission, and optical circuit switching (OCS) to improve local RE utilization and reduce grid-purchase cost. A compact compute-electricity master problem generates candidate schedules using estimated transfer delays. The framework then schedules optical circuits, verifies checkpoint delivery under shared-link capacity constraints, and revises infeasible schedules using updated delay estimates. It integrates day-ahead planning, event-triggered intraday updates, and real-time dispatch. In a five-AIDC benchmark with equal completed work and network resources, the proposed method reduces the real-time grid purchase cost by 12.50% and increases the local RE utilization by 2.724 percentage points relative to static optical operation. Sensitivity and ablation analyses indicate that OCS is particularly beneficial when renewable-rich or low-price windows shift across sites and network bottlenecks hinder timely checkpoint delivery.

Original paperChinese poster

Computing & systems

02

FALCON: FPGA-Accelerated Latency-Certifiable Occupancy Networks for Camera-Based Autonomous Driving

arXivPreprint
Research overview

A perception system that must brake for a pedestrian does not need a low average latency. It must deliver an answer before the deadline on every frame, the worst case included. Commodity edge accelerators optimize the mean through dynamic scheduling, OS jitter, thermal throttling, and contention, so their per-frame latency can be measured but not bounded. We build FALCON, a camera-based 3D occupancy front-end on the AMD Kria KR260, an embedded FPGA drawing 4.3 W idle and up to 6.6 W under inference, and make the latency guarantee layered and explicit: programmable-logic (PL) compute is cycle-bounded analytically; inference is a measured envelope over 100k-frame traces; and a watchdog enforces output delivery, publishing the previous output flagged stale when a frame is late. The deadline runs use a fixed-work proxy of six ResNet-50 DPU inferences per frame, not the full occupancy network: across three 100k-frame enforced runs, all 300k proxy frames delivered an output within the 100 ms deadline plus at most 10.2 ms, the worst of the three runs. The full six-camera FlashOcc pipeline composes to about 1.3 s per frame on the board and is not yet a 10 Hz system. The two operations the DPU cannot run, a view-transform gather and a bilinear resize, become fixed-trip-count PL IPs numerically matched to their software references. On the full Occ3D-nuScenes validation set the board reaches mIoU 29.88, 92.8% of an FP32 baseline the DPU cannot run. On a ResNet-50 probe over 100k frames the KR260 tail stays within 1.5 times its median (2.0 times for the six-inference proxy), where Jetson Orin reaches 4.4 times and the worst datacenter GPU run (NVIDIA L4) 23.6 times. The deployment recipe, HLS sources, and raw timing traces are released.

Abstract & detailed commentary

Haohua Que, Mingkai Liu, Handong Yao

Chinese abstract

A perception system that must brake for a pedestrian does not need a low average latency. It must deliver an answer before the deadline on every frame, the worst case included. Commodity edge accelerators optimize the mean through dynamic scheduling, OS jitter, thermal throttling, and contention, so their per-frame latency can be measured but not bounded. We build FALCON, a camera-based 3D occupancy front-end on the AMD Kria KR260, an embedded FPGA drawing 4.3 W idle and up to 6.6 W under inference, and make the latency guarantee layered and explicit: programmable-logic (PL) compute is cycle-bounded analytically; inference is a measured envelope over 100k-frame traces; and a watchdog enforces output delivery, publishing the previous output flagged stale when a frame is late. The deadline runs use a fixed-work proxy of six ResNet-50 DPU inferences per frame, not the full occupancy network: across three 100k-frame enforced runs, all 300k proxy frames delivered an output within the 100 ms deadline plus at most 10.2 ms, the worst of the three runs. The full six-camera FlashOcc pipeline composes to about 1.3 s per frame on the board and is not yet a 10 Hz system. The two operations the DPU cannot run, a view-transform gather and a bilinear resize, become fixed-trip-count PL IPs numerically matched to their software references. On the full Occ3D-nuScenes validation set the board reaches mIoU 29.88, 92.8% of an FP32 baseline the DPU cannot run. On a ResNet-50 probe over 100k frames the KR260 tail stays within 1.5 times its median (2.0 times for the six-inference proxy), where Jetson Orin reaches 4.4 times and the worst datacenter GPU run (NVIDIA L4) 23.6 times. The deployment recipe, HLS sources, and raw timing traces are released.

Original paperChinese poster

Resources & environment

03

Aging-Aware Online Distributed Scheduling for Lifecycle Carbon Reduction in Geo-Distributed Data Centers

arXivPreprint
Research overview

The rapid proliferation of data centers (DCs), driven by cloud computing and artificial intelligence (AI), has led to massive energy demand and carbon emissions, posing significant sustainability challenges. Carbon-aware optimization in geographically distributed data centers has been widely studied. Most existing approaches mainly focus on operational carbon emissions from server usage. However, existing literature often ignores workload-induced thermal stress, which accelerates nonlinear hardware degradation. This leads to more frequent server replacements and ultimately increases embodied carbon emissions. To address these limitations, we propose a comprehensive carbon life-cycle modeling framework for distributed data centers. Apart from operational carbon emissions, this work combines workload scheduling with a utilization-dependent exponential aging model to evaluate long-term carbon costs from server degradation. In order to solve the proposed optimization model in an online and privacy-preserving manner, an enhanced Lyapunov framework with time-varying queue shifting (TVQS) is first introduced to handle system uncertainties. Then, a zero-sum perturbation-based alternating direction method of multipliers (ZSP-ADMM) framework is developed to enable distributed coordination across geographically separated data centers while protecting locally exchanged workload information. Simulation results demonstrate that the proposed approach achieves up to 13.0% lower carbon emissions and 12.6% lower operational costs compared with benchmarks.

Abstract & detailed commentary

Junyu Lin, Wenjie Liu, Shunbo Lei, Wentian Lu, Jianhui Wang, Junhong Liu

Chinese abstract

The rapid proliferation of data centers (DCs), driven by cloud computing and artificial intelligence (AI), has led to massive energy demand and carbon emissions, posing significant sustainability challenges. Carbon-aware optimization in geographically distributed data centers has been widely studied. Most existing approaches mainly focus on operational carbon emissions from server usage. However, existing literature often ignores workload-induced thermal stress, which accelerates nonlinear hardware degradation. This leads to more frequent server replacements and ultimately increases embodied carbon emissions. To address these limitations, we propose a comprehensive carbon life-cycle modeling framework for distributed data centers. Apart from operational carbon emissions, this work combines workload scheduling with a utilization-dependent exponential aging model to evaluate long-term carbon costs from server degradation. In order to solve the proposed optimization model in an online and privacy-preserving manner, an enhanced Lyapunov framework with time-varying queue shifting (TVQS) is first introduced to handle system uncertainties. Then, a zero-sum perturbation-based alternating direction method of multipliers (ZSP-ADMM) framework is developed to enable distributed coordination across geographically separated data centers while protecting locally exchanged workload information. Simulation results demonstrate that the proposed approach achieves up to 13.0% lower carbon emissions and 12.6% lower operational costs compared with benchmarks.

Original paperChinese poster

Computing & systems

04

Stackelberg Game with Multi-Agent Transformer for ISRS-Aware Resource Re-optimization in Multi-Band Optical Networks

arXivPreprint
Research overview

The rapid expansion of generative AI is driving computing infrastructures toward interconnected AI data centers. Multi-band optical networks have become the backbone of such connectivity. To accommodate increasingly dynamic traffic demands, these networks require continual resource re-optimization to improve resource utilization and reduce service blocking. However, multi-band transmission amplifies inter-channel stimulated Raman scattering(ISRS), inducing nonlinear coupling among services. This coupling complicates re-optimization, as local adjustments perturb the global power profile, creating interdependent optimization decisions across services. Moreover, the nonlinear interactions vary with the subset of services selected for re-optimization, and inappropriate selection may reduce re-optimization effectiveness or diminish achievable benefits. To address these challenges, we propose a Stackelberg Game with Multi-Agent Transformer (SG-MAT) approach for ISRS-aware resource re-optimization. SG-MAT employs a leader-follower structure, in which the MAT-based follower models nonlinear coupling and generates coordinated channel reallocations, feeding the utilization improvements to the leader. Using this feedback, the leader identifies critical service subsets, approximating a Stackelberg equilibrium to guide global decisions and enabling consistent and efficient re-optimization. Simulation results show that SG-MAT achieves the highest utilization improvement and reduces the blocking ratio by approximately 30% under moderate traffic loads, with computational complexity comparable to benchmarks.

Abstract & detailed commentary

Jiaxin Liu, Rentao Gu, Miao Zhu, Zeguang Zou, Hui Li, Yuefeng Ji

Chinese abstract

The rapid expansion of generative AI is driving computing infrastructures toward interconnected AI data centers. Multi-band optical networks have become the backbone of such connectivity. To accommodate increasingly dynamic traffic demands, these networks require continual resource re-optimization to improve resource utilization and reduce service blocking. However, multi-band transmission amplifies inter-channel stimulated Raman scattering(ISRS), inducing nonlinear coupling among services. This coupling complicates re-optimization, as local adjustments perturb the global power profile, creating interdependent optimization decisions across services. Moreover, the nonlinear interactions vary with the subset of services selected for re-optimization, and inappropriate selection may reduce re-optimization effectiveness or diminish achievable benefits. To address these challenges, we propose a Stackelberg Game with Multi-Agent Transformer (SG-MAT) approach for ISRS-aware resource re-optimization. SG-MAT employs a leader-follower structure, in which the MAT-based follower models nonlinear coupling and generates coordinated channel reallocations, feeding the utilization improvements to the leader. Using this feedback, the leader identifies critical service subsets, approximating a Stackelberg equilibrium to guide global decisions and enabling consistent and efficient re-optimization. Simulation results show that SG-MAT achieves the highest utilization improvement and reduces the blocking ratio by approximately 30% under moderate traffic loads, with computational complexity comparable to benchmarks.

Original paperChinese poster

AI & modeling

05

Watts If? A Benchmark for Counterfactual Reasoning About the AI Data Center Buildout

arXivPreprint
Research overview

An AI data center is committed years before it draws a watt: a few discrete choices (grid or on-site gas, evaporative or dry cooling, which county to file in) fix its capital, water draw, and carbon path, and LLMs are now asked to help screen them with no test of whether they track what each commitment rules out. We introduce DCBench-440, with two arms reported separately: 200 generative questions over STRIPS worlds for five US deal archetypes, with search-verified gold answers and no tested shortcut above 12% on any question type, and 240 multiple-choice questions grounded in quoted site records, emission equations, and stated scenarios. Across open-weight deployments, accuracy spans 12.5-71.5% (generative) and 58.3-92.5% (multiple choice). One skill fails everywhere: asked to list every action available at a decision gate, no model exceeds 4.0% exact match. The strongest list 72-85% of the actions that would change the project's state but omit most permitted actions that change nothing; with those excused, the best exact match is still 24%. Code, data, and other materials are available upon request.

Abstract & detailed commentary

Pankaj Chouhan, Rajarshi Das, Aditya Dubey, Manminder Tomar, Sreekar Reddy, Samta Sharma, Satyapragnya Kar, PR Panigrahi

Chinese abstract

An AI data center is committed years before it draws a watt: a few discrete choices (grid or on-site gas, evaporative or dry cooling, which county to file in) fix its capital, water draw, and carbon path, and LLMs are now asked to help screen them with no test of whether they track what each commitment rules out. We introduce DCBench-440, with two arms reported separately: 200 generative questions over STRIPS worlds for five US deal archetypes, with search-verified gold answers and no tested shortcut above 12% on any question type, and 240 multiple-choice questions grounded in quoted site records, emission equations, and stated scenarios. Across open-weight deployments, accuracy spans 12.5-71.5% (generative) and 58.3-92.5% (multiple choice). One skill fails everywhere: asked to list every action available at a decision gate, no model exceeds 4.0% exact match. The strongest list 72-85% of the actions that would change the project's state but omit most permitted actions that change nothing; with those excused, the best exact match is still 24%. Code, data, and other materials are available upon request.

Original paperChinese poster

AI & modeling

06

Identifiability-Guided Composite Load Modeling of AI Data Centers

arXivPreprint
Research overview

The rapid growth of AI data centers introduces large, workload-dependent loads whose protection and reconnection behavior can affect power-system transient stability. Calibrating dynamic models of such loads is challenging because treating all associated elements as freely estimable may lead to weakly identified or physically confounded parameterizations. This paper proposes an identifiability-guided calibration framework for a composite load model with separate IT, cooling, and auxiliary branches. A nuisance-projected Fisher-information criterion characterizes the local identifiability of the cooling-motor composition, while a workload non-equivalence result shows that voltage-only recalibration cannot reproduce workload-dependent responses. Guided by these results, a grey-box estimator trained with branch-level supervision learns the workload-to-power relation and the cooling composition, while retaining a prescribed UPS protection law and an externally anchored reconnect-ramp duration. The learned workload relation is then distilled into a closed form for transient-stability simulation. Evaluation using 300,000 MIT Supercloud GPU power-utilization samples and 12,600 IEEE 39-bus fault scenarios yields an aggregate active-power $R^2$ of 0.948, compared with 0.856 for an LSTM baseline. Removing branch-level supervision preserves relatively high aggregate accuracy but substantially degrades cooling-component recovery. Under unseen deep voltage sags, the proposed model achieves a transient $R^2$ of 0.750, compared with 0.033 for the LSTM. Closed-loop simulations further show that cooling composition and protection behavior can affect retained-load states and voltage responses near protection thresholds.

Abstract & detailed commentary

Ding Lin, Jianhui Wang, Meng Yue, Tianqiao Zhao

Chinese abstract

The rapid growth of AI data centers introduces large, workload-dependent loads whose protection and reconnection behavior can affect power-system transient stability. Calibrating dynamic models of such loads is challenging because treating all associated elements as freely estimable may lead to weakly identified or physically confounded parameterizations. This paper proposes an identifiability-guided calibration framework for a composite load model with separate IT, cooling, and auxiliary branches. A nuisance-projected Fisher-information criterion characterizes the local identifiability of the cooling-motor composition, while a workload non-equivalence result shows that voltage-only recalibration cannot reproduce workload-dependent responses. Guided by these results, a grey-box estimator trained with branch-level supervision learns the workload-to-power relation and the cooling composition, while retaining a prescribed UPS protection law and an externally anchored reconnect-ramp duration. The learned workload relation is then distilled into a closed form for transient-stability simulation. Evaluation using 300,000 MIT Supercloud GPU power-utilization samples and 12,600 IEEE 39-bus fault scenarios yields an aggregate active-power $R^2$ of 0.948, compared with 0.856 for an LSTM baseline. Removing branch-level supervision preserves relatively high aggregate accuracy but substantially degrades cooling-component recovery. Under unseen deep voltage sags, the proposed model achieves a transient $R^2$ of 0.750, compared with 0.033 for the LSTM. Closed-loop simulations further show that cooling composition and protection behavior can affect retained-load states and voltage responses near protection thresholds.

Original paperChinese poster

AI & modeling

07

Converter-Aware Coordination of Computing Flexibility in Behind-the-Meter Data Centers

arXivPreprint
Research overview

Data centers are emerging as large electricity consumers whose demand can be reshaped through workload scheduling. However, computing flexibility in behind-the-meter facilities does not automatically translate into electrically realizable power flexibility. Ignoring converter and network operating limits may cause converter overloads, protection trips, and interruptions to power supply and computing services. This paper proposes a converter-aware intraday scheduling methodology. First, a task-level mixed-integer linear formulation preserves synchronous training configurations and completion requirements, while Minkowski-sum aggregation and Shapley--Folkman convexification yield a linear inference-pool representation without unit-level binary variables. The latter admits a conditional relative relaxation-gap bound that decreases inversely with pool size. Second, a four-node electrical model links computing demand, on-site injections, and grid exchange to converter and network limits through lifted voltage variables and second-order cone relaxation. Finally, a mixed-integer model coordinates workloads, photovoltaic generation, energy storage, and grid purchases. Case studies show that electrical limits reshape scheduling and renewable utilization, while on-site resources reduce grid dependence. Under the studied conditions, fixed training cannot support full inference service within voltage limits, whereas coordinated scheduling achieves negligible inference shortage and passes verification against the original alternating-current model. These findings demonstrate the role of computing--electrical coordination in realizing the operational value of workload flexibility.

Abstract & detailed commentary

Ruolan Cui, Ruizhang Yang, Chenxi Hu, Franxis Yunhe Hou

Chinese abstract

Data centers are emerging as large electricity consumers whose demand can be reshaped through workload scheduling. However, computing flexibility in behind-the-meter facilities does not automatically translate into electrically realizable power flexibility. Ignoring converter and network operating limits may cause converter overloads, protection trips, and interruptions to power supply and computing services. This paper proposes a converter-aware intraday scheduling methodology. First, a task-level mixed-integer linear formulation preserves synchronous training configurations and completion requirements, while Minkowski-sum aggregation and Shapley--Folkman convexification yield a linear inference-pool representation without unit-level binary variables. The latter admits a conditional relative relaxation-gap bound that decreases inversely with pool size. Second, a four-node electrical model links computing demand, on-site injections, and grid exchange to converter and network limits through lifted voltage variables and second-order cone relaxation. Finally, a mixed-integer model coordinates workloads, photovoltaic generation, energy storage, and grid purchases. Case studies show that electrical limits reshape scheduling and renewable utilization, while on-site resources reduce grid dependence. Under the studied conditions, fixed training cannot support full inference service within voltage limits, whereas coordinated scheduling achieves negligible inference shortage and passes verification against the original alternating-current model. These findings demonstrate the role of computing--electrical coordination in realizing the operational value of workload flexibility.

Original paperChinese poster

Resources & environment

08

Estimating data center water use: Best practices and critical questions

arXivPreprint
Research overview

Concerns are growing about the water use of data centers. To quantify the scales, drivers, and possible trajectories of this water use, analytical estimation is required. However, current estimation methods and results vary widely due, in part, to a lack of established best practices. This variance is illustrated with a U.S. case study demonstrating a roughly 24-fold difference in possible outcomes based on observed U.S. study design variations. To address these challenges, this review synthesizes 14 best practices for advancing the science and utility of data center water use estimation. These proposed best practices can also be used as critical questions for stakeholders when evaluating the quality of any study. Using a structured rubric, it further assesses the literature to date (31 studies) against these best practices. The assessment reveals important opportunities for improvement and standardization in future study scopes, clarity, methods, and scientific knowledge building utility. It further finds that, while many studies provide reasonable transparency, scope definitions, replicability, and uncertainty treatment, many fall short in scientific justification, data representativeness, transparency on hydropower assumptions, terminological consistency, and meaningful discussions of limitations and future work. Recommendations are proposed for analysts, stakeholders, and policymakers to leverage these findings to help build a vibrant data center water use research community. Finally, this review can also be used as a basic primer for understanding data center cooling configurations and water use among analysts, policymakers, the media, and the public.

Abstract & detailed commentary

Eric Masanet

Chinese abstract

Concerns are growing about the water use of data centers. To quantify the scales, drivers, and possible trajectories of this water use, analytical estimation is required. However, current estimation methods and results vary widely due, in part, to a lack of established best practices. This variance is illustrated with a U.S. case study demonstrating a roughly 24-fold difference in possible outcomes based on observed U.S. study design variations. To address these challenges, this review synthesizes 14 best practices for advancing the science and utility of data center water use estimation. These proposed best practices can also be used as critical questions for stakeholders when evaluating the quality of any study. Using a structured rubric, it further assesses the literature to date (31 studies) against these best practices. The assessment reveals important opportunities for improvement and standardization in future study scopes, clarity, methods, and scientific knowledge building utility. It further finds that, while many studies provide reasonable transparency, scope definitions, replicability, and uncertainty treatment, many fall short in scientific justification, data representativeness, transparency on hydropower assumptions, terminological consistency, and meaningful discussions of limitations and future work. Recommendations are proposed for analysts, stakeholders, and policymakers to leverage these findings to help build a vibrant data center water use research community. Finally, this review can also be used as a basic primer for understanding data center cooling configurations and water use among analysts, policymakers, the media, and the public.

Original paperChinese poster